Structural analysis of a residence made with thin walled cold formed steel galvanized members under procedures of dry construction method – Light Steel Framing (LSF)

dc.contributorGomes, Herbert Martins
dc.creatorBatista, Rafael Cavicchioli
dc.date2011-08-30T06:01:15Z
dc.date2011
dc.identifierhttp://hdl.handle.net/10183/31423
dc.identifier000780807
dc.descriptionO Mercado da construção civil no Brasil ainda é marcado pela predominância de métodos construtivos praticamente artesanais, caracterizados pelo grande desperdício de matéria prima e também pela baixa eficiência. Visando solucionar estes problemas, propõemse o uso de novos métodos construtivos, de concepção racional e que sejam facilmente industrializados. Neste sentido, o presente trabalho propõe-se a verificar o desempenho e o comportamento estrutural de uma estrutura residencial constituída segundo um método construtivo de concepção racional mundialmente reconhecido, o Light Steel Framing. Onde, para isso, foi utilizado o mais novo método adotado pela norma brasileira de estruturas constituídas de perfis de aço formados a frio (NBR 14762, 2010), o Método da Resistência Direta. O estudo conclui que o comportamento e desempenho da estrutura em análise serão aprovados segundo os procedimentos verificados da norma brasileira vigente quando prédimensionados usando indicações do CBCA (Centro Brasileiro da Construção em Aço), e também alerta para a tomada de cuidados no uso da verificação via Método da Resistência Direta em situações específicas, devido às limitações do mesmo.
dc.descriptionThe Brazilian market of civil construction still marked by the predominance of handmade construction method, characterized by the lower efficiency and for a large waste of materials. In order to solve these problems, one proposes the use of new constructions methods, design to avoid waste and be easily industrialized. In this sense, this present work will be determined to check and verify the behavior and performance of a structure made under procedures of dry construction method, the Light Steel Framing Method. For this, it will be used the newer method adopted by the Brazilian Standard of thin walled cold formed steel structure (NBR 14762, 2010), the Direct Strength Method. The study concludes that the analyzed structure would be approved by the Brazilian norm procedures if designed in accordance with the CBCA (Brazilian Center of Steel Construction) reports, and also warns to take care on the use of Direct Strength Method on specific situations, because of its limitations.
dc.formatapplication/pdf
dc.languagepor
dc.rightsOpen Access
dc.subjectStructural analysis
dc.subjectLight steel framing
dc.subjectCold formed sheet
dc.subjectBuckling
dc.subjectEngenharia mecânica
dc.titleAnálise estrutural de uma residência constituída por perfis de aço galvanizados de pequena espessura formados a frio segundo o sistema construtivo a seco - Light Steel Framing (LSF)
dc.titleStructural analysis of a residence made with thin walled cold formed steel galvanized members under procedures of dry construction method – Light Steel Framing (LSF)
dc.typeTrabalho de conclusão de graduação


Este ítem pertenece a la siguiente institución