Assessment of left ventricular diastolic function in hypertensive patients under different hemodynamic conditions: comparative study between transmitral and tissue doppler echocardiography

dc.creatorDanzmann, Luiz Cláudio
dc.creatorFreitas, Valéria Centeno de
dc.creatorAraujo, Luiz Felipe Lopes
dc.creatorTorres, Marco Antonio Rodrigues
dc.date2010-04-16T09:13:57Z
dc.date2006
dc.identifier0066-782X
dc.identifierhttp://hdl.handle.net/10183/20295
dc.identifier000580179
dc.descriptionOBJETIVO Avaliar o comportamento das velocidades de movimentação diastólica do segmento VE septal posterior basal justa-anular, obtidos pelo Doppler tissular em relação às velocidades do fl uxo transmitral de hipertensos, submetidos à sobrecarga de pré-carga por elevação dos membros inferiores por 5 minutos, e durante 1 minuto de handgrip (condições 1 e 2, respectivamente). MÉTODOS Vinte e cinco pacientes ambulatoriais (15 homens, 52±11 anos), com hipertensão arterial sistêmica >3 anos, com as seguintes variáveis do Doppler transmitral: E, A e E/A, e do Doppler tissular: E’, A’ e E’/A’, obtidas na situação basal e nas condições 1 e 2. A comparação dos resultados (basal vs. condições 1 e 2) foi realizada por teste t pareado. RESULTADOS E(cm/s) variou de 68,88 ± 11,94 para 75,82 ± 15,71* enquanto E’(cm/s) variou de 8,22 ± 2,30 para 8,31 ± 2,24 na condição 1 (p<0,05). Adicionalmente, a comparação dos percentuais (%) de variação dos índices de Doppler mitral com os % de seus correspondentes medidos por Doppler tissular revelou diferença signifi cativa entre E e E’, com incremento da pré-carga (p=0,01). CONCLUSÃO Em pacientes com VE adaptado à hipertensão arterial sistêmica, o índice E’ modifi cou-se menos do que o índice E após manobra de elevação de pré-carga, o que deve orientar no sentido de sua maior utilização na avaliação da função diastólica por ecocardiografia.
dc.descriptionOBJECTIVE To evaluate the behavior of LV diastolic displacement velocities of basal posterior septum near mitral ring segment obtained by tissue Doppler in relation to mitral fl ow velocities of hypertensive subjects, submitted to preload increase by left inferior limbs elevation for 5 minutes, and during 1 minute of handgrip (conditions 1 and 2, respectively). METHODS Twenty fi ve outpatients (15 men, 52±11 years), with arterial hypertension > 3 years, by the transmitral fl ow Doppler variables: E, A and E/A, and of tissue Doppler: E’, A’ and E’/A’, in basal situation and in conditions 1 and 2. For comparison of results in basal situation with conditions 1 and 2 a paired t test was applied. RESULTS E(cm/s) varied from 68,88 ± 11,94 to 75,82 ± 15,71* and E’(cm/s) varied from 8,22 ± 2,30 to 8,31 ± 2,24 in condition 1 (p<0.05). In addition, a comparison of variation percent (%) of Doppler transmitral indices with corresponding tissue Doppler indices variation % showed a signifi cant difference between E and E’, with preload increase (p=0.01). CONCLUSION Patients with left ventricular adaptation to systemic arterial hypertension showed less modifi cation of the index E´ than E, after preload increase maneuver, an evidence that may suggest its more ample utilization in the context of echocardiographic left ventricular diastolic function evaluation.
dc.formatapplication/pdf
dc.languagepor
dc.relationArquivos brasileiros de cardiologia. São Paulo, SP. Vol. 87, n. 2 (ago. 2006), p. 121-127.
dc.rightsOpen Access
dc.subjectLeft ventricular diastolic function
dc.subjectArterial hypertension
dc.subjectTissue Doppler
dc.subjectHipertensão
dc.subjectVentrículos do coração
dc.titleAnálise da função diastólica do ventrículo esquerdo em hipertensos sob variação de condições hemodinâmicas provocadas : estudo comparativo entre o doppler transmitral e tissular
dc.titleAssessment of left ventricular diastolic function in hypertensive patients under different hemodynamic conditions: comparative study between transmitral and tissue doppler echocardiography
dc.typeArtigo de periódico
dc.typeNacional


Este ítem pertenece a la siguiente institución