dc.descriptionThis article presents eight curves of waste water generation, 2 in commercial buildings, 2 in office buildings, 2 in residential establishments, 1 in food industry, and 1 in a university. Curves are presented in terms of percentage of the total flow in a day. They were estimated by measuring instantaneous flow every 5 minutes during 24 hours, in order to establish the difference in the wastewater flow that enters to wastewater treatment plants of each kind of wastewater generator. Values obtain were processed to produce graphics in 30 minutes range time. In every case, average flow is equivalent to 2.1% of the total flow in a day. Commercial discharges present peak flow of 2.4 to 3.6 times average flow; office buildings discharges present peak flow of 2 to 2.1 times average flow; and residential discharges presents peak flows of 1.9 to 2.2 times average flow.en-US
dc.descriptionEste artículo presenta 8 curvas de generación de caudal de aguas residuales, dos de establecimientos comerciales, dos de oficinas, dos de condominios residenciales, una de industria alimenticia y una de universidad. Las curvas son presentadas en porcentajes del caudal total generado en un día. Fueron estimadas en base a mediciones de caudal instantáneo cada 5 minutos, durante 24 horas, con la finalidad de establecer las diferencias en el comportamiento del caudal que ingresa a los sistemas de tratamiento de aguas residuales de cada tipo de ente generador. Los valores obtenidos de las mediciones se procesaron para producir gráficas en rangos de tiempo de 30 minutos. En todos los casos, el caudal medio es equivalente al 2.1% del total del caudal descargado en un día. Las descargas comerciales tienen picos de caudal máximo entre 2.4 y 3.6 veces el caudal medio, mientras que la descarga de edificios de oficinas tienen picos de 2 y 2.1 veces el caudal medio, y para las descargas domésticas se encontraron picos de 1.9 a 2.2 veces el caudal medio.es-ES
dc.formatapplication/pdf
dc.languagespa
dc.publisherUniversidad de San Carlos de Guatemalaes-ES
dc.relationhttps://revistas.usac.edu.gt/index.php/asa/article/view/1441/912
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/4.0es-ES
dc.sourceAgua, Saneamiento & Ambiente; Vol. 11 No. 1 (2016); 37-43en-US
dc.sourceAgua, Saneamiento & Ambiente; Vol. 11 Núm. 1 (2016); 37-43es-ES
dc.source2224-9958
dc.source2222-2499
dc.subjectAnálisis de datoses-ES
dc.subjectmedición de caudales-ES
dc.subjectdescargas de aguas residualeses-ES
dc.subjectcurva de caudales-ES
dc.subjectplanta de tratamiento de aguas residualeses-ES
dc.subjectData analysisen-US
dc.subjectflow measurementen-US
dc.subjectwastewater dischargeen-US
dc.subjectflow curvesen-US
dc.subjectwastewater treatment plantsen-US
dc.titleEstimación de curvas de caudal para el diseño de sistemas de tratamiento de aguas residualeses-ES