dc.creatorFeng Jin
dc.creatorSERGUEI STEPANOV
dc.creatorJacob Khurgin
dc.creatorPONCIANO RODRIGUEZ MONTERO
dc.date2007-09
dc.date.accessioned2023-07-25T16:22:44Z
dc.date.available2023-07-25T16:22:44Z
dc.identifierhttp://inaoe.repositorioinstitucional.mx/jspui/handle/1009/961
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7806160
dc.descriptionWe demonstrate experimentally the detection, in a remote and noncontact manner, of human life signs using a high-sensitivity pulsed laser vibrometer. The high surface displacement detection sensitivity of the photo-electromotive-force (photo-EMF) pulsed laser vibrometer, combined with its tolerance to the presence and moderate temporal variations of optical speckles in the light beams, allows the detection of human heartbeats, breathing, and gross physical movement from essentially any part of a human subject’s surface, even in the presence of clothing, all the while without limiting the interrogation points to specific locations like the chest and carotid areas. In contrast to conventional Michelson interferometer-based laser vibrometers, the photo-EMF pulsed laser vibrometer (PPLV) does not require the use of retroreflective tapes or special electronic filtering to retrieve vividly the biological subject’s life signs. Experimental results demonstrating the detection of life signs from various parts of biological subjects’ bodies, with or without the coverage of clothing are presented. We also demonstrate the monitoring of a human subject’s heart movements by interrogating the back of his/her hand. Results from using PPLV to determine extremity blood circulation at various levels of proximal occluding pressures are also presented.
dc.formatapplication/pdf
dc.languageeng
dc.publisherIEEE Sensors Journal
dc.relationcitation:Wang, Ch., et al., (2007). Human life signs detection using high-sensitivity pulsed laser vibrometer, IEEE Sensors Journal, Vol. 7 (9): 1370-1376
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.subjectinfo:eu-repo/classification/Biomedical acoustics/Biomedical acoustics
dc.subjectinfo:eu-repo/classification/Biomedical measurements/Biomedical measurements
dc.subjectinfo:eu-repo/classification/Medical diagnosis/Medical diagnosis
dc.subjectinfo:eu-repo/classification/Optical velocity measurement/Optical velocity measurement
dc.subjectinfo:eu-repo/classification/Photodetectors/Photodetectors
dc.subjectinfo:eu-repo/classification/Vibration measurement/Vibration measurement
dc.subjectinfo:eu-repo/classification/cti/1
dc.subjectinfo:eu-repo/classification/cti/22
dc.subjectinfo:eu-repo/classification/cti/2209
dc.subjectinfo:eu-repo/classification/cti/2209
dc.titleHuman life signs detection using high-sensitivity pulsed laser vibrometer
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion
dc.audiencestudents
dc.audienceresearchers
dc.audiencegeneralPublic


Este ítem pertenece a la siguiente institución