dc.creatorHongn, Marcos Ezequiel
dc.creatorFlores Larsen, Silvana Elinor
dc.creatorAltamirano, Martín
dc.creatorGea, Marcelo Daniel
dc.creatorBárcena, Humberto
dc.date2014
dc.date2022-07-11T18:14:24Z
dc.date.accessioned2023-07-15T07:13:13Z
dc.date.available2023-07-15T07:13:13Z
dc.identifierhttp://sedici.unlp.edu.ar/handle/10915/139290
dc.identifierhttp://portalderevistas.unsa.edu.ar/index.php/averma/article/view/1998
dc.identifierissn:2314-1433
dc.identifierissn:2796-8111
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7479659
dc.descriptionEn el presente trabajo se llevó a cabo un análisis geométrico tridimensional que permite estimar el desplazamiento instantáneo de los haces reflejados de luz sobre el absorbedor de un concentrador solar del tipo Fresnel lineal. Las pérdidas debidas a este efecto deben ser tenidas en cuenta en la etapa de diseño y para cálculos de eficiencia. Es por ello que se define, además de la longitud no iluminada del absorbedor (m), un factor que representa la fracción de absorbedor que permanece iluminado, ambos en términos medios diarios. Se considera el caso particular del sistema LFC instalado en la localidad de San Carlos y se evalúa la variación de estos parámetros a lo largo del año, en función de la distancia espejo - absorbedor. Para los meses de invierno la longitud sin iluminar de absorbedor puede superar los 8 metros, provocando, en promedio diario, que el 30% de la longitud del absorbedor (24 metros) no intercepte haces reflejados por el campo de espejos. Se analiza una propuesta de mejora, como alternativa para atenuar las pérdidas ópticas que afectan de manera considerable a prototipos de pequeña escala.
dc.descriptionThe present work shows a tridimensional geometric analysis that allows estimate instantaneous non-illuminated length of absorber in Linear Fresnel Concentrator systems. These optic losses must be considered during development stage and efficiency calculus. Also a factor that represents the illuminated fraction of absorber is defined, through mean daily values. The specific case of a LFC located in San Carlos was studied, evaluating the annual variation of these parameters as a function of the mirror-receptor distance. For winter months the non-illuminated length can exceed 8 meters, this effect causes that 30% of absorber length (24 meters) remains non illuminated during the day. Finally, a constructive improvement was analized with the aim of mitigating the optical losses produces by the ‘end-effect’.
dc.descriptionAsociación Argentina de Energías Renovables y Medio Ambiente (ASADES)
dc.formatapplication/pdf
dc.format19-26
dc.languagees
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.subjectIngeniería
dc.subjectCiencias Exactas
dc.subjectconcentrador Fresnel lineal
dc.subjectlongitud no iluminada
dc.subjectpérdidas ópticas
dc.subjectFresnel Linear Concentrator
dc.subjectnon-iluminated length
dc.subjectoptical losses
dc.titleLongitud no iluminada de absorbedor en un reflector Fresnel lineal en San Carlos, Salta
dc.typeArticulo
dc.typeArticulo


Este ítem pertenece a la siguiente institución