dc.creatorFushimi, Alberto
dc.creatorZárate, L.
dc.creatorHall, Marcos Fernando
dc.creatorMoreda, M.
dc.creatorGómez, M.
dc.date2008
dc.date2020-04-30T15:50:08Z
dc.date.accessioned2023-07-14T19:34:39Z
dc.date.available2023-07-14T19:34:39Z
dc.identifierhttp://sedici.unlp.edu.ar/handle/10915/94655
dc.identifierissn:0329-5184
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7435854
dc.descriptionEn el presente trabajo sus autores intentan mostrar los beneficios que pueden ser obtenidos a partir de la utilización de calor de baja temperatura en sistemas de District Heating (DH) en nuestro País donde no se ha desarrollado ningún proyecto de este tipo, explicando los conceptos básicos del funcionamiento y características intrínsecas de los sistemas de DH, para luego identificar sus ventajas e implementación, especialmente en zonas australes frías de nuestro País. Se estudió y evaluó las performances de ciclos de vapor y turbinas de gas mediante modelos computacionales desarrollados en hoja de cálculo. La eficiencia de un sistema de Cogeneración debe medirse a través del ahorro de recursos que ésta produce frente a un sistema de referencia. Los análisis realizados fueron sobre los sistemas de generación eléctrica convencionales para un ciclo de vapor y una Turbina de Gas encontrando resultados favorables en ambos, para el ahorro de recursos debido al DH, en lugar de estufas a gas de tiro balanceado para producir el mismo calor.
dc.descriptionAutors of presently work will try to show the benefits that could be obtained from the use of low temperature heat in systems of District Heating (DH) in our Country where no Project of this type was undertaken so far. They explain the basic concepts of the operation and intrinsic characteristics of DH systems, and identify their advantages and how they could be implemented, specially in the cold weather Southern Area of the Country. They have studied performances of Steam, and Gas Tubine cycles by computational models developed in Spreadsheet. The quality of a cogeneration system has to be measured through the saving of resources that it produces compared to a reference system. Good results regarding saving resources were obtained in the analysis of conventional Steam and Gas Turbine for electricity generation systems when these machines are linked to a DH system instead of use traditional way to warm our rooms with balanced draft natural gas heaters.
dc.descriptionAsociación Argentina de Energías Renovables y Medio Ambiente (ASADES)
dc.formatapplication/pdf
dc.format33-40
dc.languagees
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
dc.subjectIngeniería
dc.subjectuso eficiente de la energía
dc.subjectuso racional de la energía
dc.subjectcogeneración
dc.subjectDistrict Heating
dc.subjectCalefacción
dc.titleEstudio del District Heating : Aplicación a partir de centrales térmicas
dc.typeArticulo
dc.typeArticulo


Este ítem pertenece a la siguiente institución