dc.contributor | Lancheros Bonilla, Sonia | |
dc.contributor | Universidad Santo Tomas | |
dc.creator | Moncada Velasquez, Juan Camilo | |
dc.creator | Bermúdez Ramírez, Claudia Priscila | |
dc.creator | La Rotta Velandia, Irmis Alejandra | |
dc.date.accessioned | 2023-01-19T15:13:58Z | |
dc.date.accessioned | 2023-06-12T16:03:48Z | |
dc.date.available | 2023-01-19T15:13:58Z | |
dc.date.available | 2023-06-12T16:03:48Z | |
dc.date.created | 2023-01-19T15:13:58Z | |
dc.date.issued | 2023-12-06 | |
dc.identifier | Moncada Velásquez, J. C., Bermúdez Ramírez, C. P. y La Rotta Velandia, I. A. (2022). Evaluación In Vitro de la Exactitud de los Localizadores Electrónicos de Ápice: Ifive de Denjoy ®. Airpex de Eigthteeth ®, Propex Pixi de Dentsply ® Con Relación al Pre-Ensanchamiento. [Tesis de Especialización]. Universidad Santo Tomás. Bucaramanga, Colombia | |
dc.identifier | http://hdl.handle.net/11634/48667 | |
dc.identifier | reponame:Repositorio Institucional Universidad Santo Tomás | |
dc.identifier | instname:Universidad Santo Tomás | |
dc.identifier | repourl:https://repository.usta.edu.co | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/6658461 | |
dc.description.abstract | Introduction: Accuracy in the measurement of the definitive working length is a vital step in endodontic treatments. The electronic method in recent decades has stood out as the most accurate method. The pre-widening of the coronal third is intended to provide an access route to the initial apical file (LAI) and has been planned as an adjuvant in the chemo-mechanical preparation protocol Objective: To evaluate the accuracy of Denjoy® Ifive locators (IF), Air-pex by Eighteeth®(AP) and Propex-Pixi by Dentsply®(PP) to determine the working length in teeth with and without coronal pre-reaming. Materials and Methods: 40 extracted single-rooted teeth were used and their working length without pre-enlargement and with pre-enlargement was determined by visual measurement and 3 LEA; taking the visual measurement as reference and the measurements of each device were compared. Measurements were calculated using the Shapiro-Wilk test, for homogeneity of variances with the Levene test. Paired t-student test and data were also compared using the ANOVA test and Dunnet's post-test of multiple comparisons. Results: PP had an accuracy of 98.6%; IF had a precision of 98.2% and AP had a precision of 96.8% accuracy. Pre-spreading improved measurement accuracy for AP and had no relevance for PP and IF measurements. | |
dc.language | spa | |
dc.publisher | Universidad Santo Tomás | |
dc.publisher | Especialización Endodoncia | |
dc.publisher | Facultad de Odontología | |
dc.relation | Abdelsalam, N., & Hashem, N. (2020). Impact of Apical Patency on Accuracy of Electronic Apex Locators: In Vitro Study. . Journal of Endodontics, 46(4), 514. | |
dc.relation | Ali, R., Okechukwu, N. C., Brunton, P., & Nattress, B. (2013). An overview of electronic apex locators: part 2. British Dental Journal, 214(5), 231. | |
dc.relation | Azabal, M., García, O. D., & De la Macorra, J. C. (2004). Accuracy of the Justy II Apex locator in determining working length in simulated horizontal and vertical fractures . International Endodontic Journal. , 37(3), 177. | |
dc.relation | Baldi, J., Victorino, F., Bernardes, R., de Moraes, I., Bramante, C., García, R., & Bernardineli, N. (2007). Influence of embedding media on the assessment of electronic apex locators. Journal Endod, 33(4), 479 | |
dc.relation | Baugh, D., & Wallace, J. (n.d.). The role of apical instrumentation in root canal treatment: a review of the literature. Journal of endodontics, 31(5), 340. | |
dc.relation | Brito, J. M., Camilo, C. C., Moreira, J. G., Pecora, J. D., & Sousa, N. M. (2012). Effect of pre flaring and file size on the accuracy of two electronic apex locators. J Appl Oral Sci. , 20, 543. | |
dc.relation | Custer, L. E. (1918). Exact Methods of Locating the Apical Foramen. The Journal of the National Dental Association., 5(8), 819. | |
dc.relation | de Camargo, É. J., Zapata, R. O., Medeiros, P. L., Bramante, C. M., Bernardineli, N., Garcia, R. B., & Duarte, M. A. (2009). Influence of preflaring on the accuracy of length determination with four electronic apex locators. J Endod. , 35(9), 1302 | |
dc.relation | Dominici, J., Eleazer, P., Clark, S., Staat, R., & Scheetz, J. (2001). Disinfection/sterilization of extracted teeth for dental student use. . J Dent Educ. , 65(11), 1281. | |
dc.relation | Eigtheeth. (2021, Diciembre 21). Changzhou Sifary Medical Technology Co.,Ltd.-R&D C. hangzhou Sifary Medical Technology Co.,Ltd.-R&D,manufacture,marketing and service integration (eighteeth.com) | |
dc.relation | ElAyouti, A., Hülber, J. M., Judenhofer, M. S., Connert, T., Mannheim, J. G., Löst, C., & Von, O. C. (2014). Frequency of overinstrumentation with an acceptable radiographic working length. JOE, 40(8), 1099. | |
dc.relation | ElAyouti, A., Weiger, R., & Löst, C. (2001). The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. Journal of Endodontics, 27(1), 52. | |
dc.relation | ElAyouti, A., Weiger, R., & Löst, C. (2002). Apical constriction: location and dimensions in molars-a micro-computed tomography study. Journal of endodontics, 28(2), 119. | |
dc.relation | Estrela, C., Couto, G. S., Bueno, M. R., Bueno, K. G., Estrela, L. R., Porto, O. C., & Diógenes, A. (2018). Apical Foramen Positio. 44(11), 1748. | |
dc.relation | Fadi, F. (2015). The Gates-Glidden bur: the search continues. Journal of the history of dentistry., 63(1). | |
dc.relation | Ferreira, I., Braga, A. C., & Pina, V. I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. Eur Endod J. , 4(2), 75. | |
dc.relation | Fogarty, T. J., & Montgomery, S. (1991). Effect of preflaring on canal transportation. . Evaluation of ultrasonic, sonic, and conventional techniques. Comparative Study, 72(3), 350. | |
dc.relation | Gordon, M. P., & Chandler, N. P. (2004). Electronic apex locators. International journal of endodontics, 37(7), 437. | |
dc.relation | Hasegawa, K., Hzuja, H., Takei, M., Goto, N., Nihei, M., & Ohashi, M. (1986). A new method and apparatus for measuring root canal length. The Journal of Nihon University School of Dentistry, 28(2), 128. | |
dc.relation | Huang, L. (1987). An experimental study of the principle of electronic root canal measurement. . Journal of endodontics, 13(2), 64. | |
dc.relation | Kaufman, A., Keila, S., & Yoshpe, M. (2002). Accuracy of a new apex locator: An in vitro study. Int Endod J , 35(2), 192 | |
dc.relation | Keratiotis, G., Kournetas, N., Agrafioti, A., & Kontakiotis, E. G. (2019). UA comparative evaluation of two working length determination methods. Australian Endodontic Journal, 45(3), 336. | |
dc.relation | León, L. M., Cabanillas, B. D., Areal, Q. V., Martín, G. J., Jiménez, S. M., Saúco, M. J., & Segura, E. J. (2021). Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis. J Clin Med., 10(13), 2760 | |
dc.relation | Mandlik, J., Shah, N., Pawar, K., Gupta, P., Singh, S., & Shaik, S. A. (2013, July). An in vivo Evaluation of Different Methods of Working Length Determination. The Journal of Contemporary Dental Practice, 14(4), 644. | |
dc.relation | Martins, J. N., & al., e. (2014). Clinical Efficacy of Electronic Apex Locators: Systematic . Review JOE, 40(6), 777. | |
dc.relation | Morgental, R. D., Vier-Pelisser, F. V., Luisi, S. B., Cogo, D. M., & Kopper, P. M. (2011). Preflaring effects on the accuracy of three electronic apex locators. . Revista Odonto Ciência, 26, 335. | |
dc.relation | Nagrani, A., Sanap, A., Mategaonkar, S., Khade, S., & Krishnakumar, K. (2021). Comparative Evaluation of Preflaring Versus Non-Preflaring on the Accuracy of Electronic Apex Locators-a Systematic Review. . MAR Dental Sciences. | |
dc.relation | Nekoofar, M. H., Ghandi, M. M., Hayes, S. J., & Dummer, P. M. (2006). 3. Nekoofar M, Ghandi M , Hayes S, Dummer P. The fundamental operating principles of electronic root canal length measurement devices. . International Endodontic Journal. , 39(8), 609. | |
dc.relation | Oliveira, T., Vivacqua, G. N., Bernardes, R., Vivan, R., Duarte, M., & Vasconcelos, B. (2017). Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols. Journal of Endodontics, 43(10), 1667. | |
dc.relation | Pécora, J. D., Capelli, A., Guerisoli, D. M., Spanó, J. C., & Estrela, C. (2005). Influence of cervical preflaring on apical file size determination. Int Endoj J., 38(7), 435. | |
dc.relation | Pishipati, K. V. (2013). An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method. Iranian Endod Journal. , 8(3), 114. | |
dc.relation | Plotino, G., Nagendrababu, V., Bukiet, F., Grande, N. M., Veettil, S. K., De-Deus, G., & Ahmed, H. M. (2020). Influence of Negotiation, Glide Path, and Preflaring Procedures on Root Canal Shaping-Terminology, Basic Concepts, and a Systematic Review. . Journal of Endodontics, 46(6), 729. | |
dc.relation | Ricucci, D., & Langeland, K. (1998). Apical limit of root canal instrumentation and obturation, part 1. Literature review. International endodontic journal, 31(6), 409. | |
dc.relation | Roland, D., Andelin, W., Browning, D., Hsu, G., & Torabinejad, M. (2002). The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. Journal of Endodontics, 28(7), 545. | |
dc.relation | Saito, T., & Yamashita, Y. (1990). Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K file and the root canal irrigants. Dentistry in Japan, 27(1), 72. | |
dc.relation | Saritha, V., Raghu, H., Kumar, T., Totad, S., Kamatagi, L., & Saraf, P. (2021). The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study. . J Conserv Dent., 24(1), 46. | |
dc.relation | Serna, P. G., Gomes, A. S., Flores, T. J., Madla, C. E., Rodríguez, D. I., & Martínez, G. G. (2020). Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex . Pixi. JOE. , 46(2), 161. | |
dc.relation | Sunada, I. (1962). Nuevo método para medir la longitud del conducto radicular. Revista de investigación dental, 41(2), 387. | |
dc.relation | Suryantoro, R., Meidyawati, R., & Suprastiwi, E. (2017). The effect of coronal preflaring on the accuracy of two electronic apex locators . Journal of Physics: Serie de conferencias, 884(1). | |
dc.relation | Yamaguchi, M., Noiri, Y., Itoh, Y., Komichi, S., Yagi, K., Uemura, R., & Ebisu, S. (2018). Factors that cause endodontic failures in general practices in Japan . BMC Salud Bucal., 18(1), 5 | |
dc.rights | Abierto (Texto Completo) | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.title | Evaluación In Vitro de la Exactitud de los Localizadores Electrónicos de Ápice: Ifive de Denjoy ®. Airpex de Eigthteeth ®, Propex Pixi de Dentsply ® Con Relación al Pre-Ensanchamiento | |