dc.contributorLancheros Bonilla, Sonia
dc.contributorUniversidad Santo Tomas
dc.creatorMoncada Velasquez, Juan Camilo
dc.creatorBermúdez Ramírez, Claudia Priscila
dc.creatorLa Rotta Velandia, Irmis Alejandra
dc.date.accessioned2023-01-19T15:13:58Z
dc.date.accessioned2023-06-12T16:03:48Z
dc.date.available2023-01-19T15:13:58Z
dc.date.available2023-06-12T16:03:48Z
dc.date.created2023-01-19T15:13:58Z
dc.date.issued2023-12-06
dc.identifierMoncada Velásquez, J. C., Bermúdez Ramírez, C. P. y La Rotta Velandia, I. A. (2022). Evaluación In Vitro de la Exactitud de los Localizadores Electrónicos de Ápice: Ifive de Denjoy ®. Airpex de Eigthteeth ®, Propex Pixi de Dentsply ® Con Relación al Pre-Ensanchamiento. [Tesis de Especialización]. Universidad Santo Tomás. Bucaramanga, Colombia
dc.identifierhttp://hdl.handle.net/11634/48667
dc.identifierreponame:Repositorio Institucional Universidad Santo Tomás
dc.identifierinstname:Universidad Santo Tomás
dc.identifierrepourl:https://repository.usta.edu.co
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6658461
dc.description.abstractIntroduction: Accuracy in the measurement of the definitive working length is a vital step in endodontic treatments. The electronic method in recent decades has stood out as the most accurate method. The pre-widening of the coronal third is intended to provide an access route to the initial apical file (LAI) and has been planned as an adjuvant in the chemo-mechanical preparation protocol Objective: To evaluate the accuracy of Denjoy® Ifive locators (IF), Air-pex by Eighteeth®(AP) and Propex-Pixi by Dentsply®(PP) to determine the working length in teeth with and without coronal pre-reaming. Materials and Methods: 40 extracted single-rooted teeth were used and their working length without pre-enlargement and with pre-enlargement was determined by visual measurement and 3 LEA; taking the visual measurement as reference and the measurements of each device were compared. Measurements were calculated using the Shapiro-Wilk test, for homogeneity of variances with the Levene test. Paired t-student test and data were also compared using the ANOVA test and Dunnet's post-test of multiple comparisons. Results: PP had an accuracy of 98.6%; IF had a precision of 98.2% and AP had a precision of 96.8% accuracy. Pre-spreading improved measurement accuracy for AP and had no relevance for PP and IF measurements.
dc.languagespa
dc.publisherUniversidad Santo Tomás
dc.publisherEspecialización Endodoncia
dc.publisherFacultad de Odontología
dc.relationAbdelsalam, N., & Hashem, N. (2020). Impact of Apical Patency on Accuracy of Electronic Apex Locators: In Vitro Study. . Journal of Endodontics, 46(4), 514.
dc.relationAli, R., Okechukwu, N. C., Brunton, P., & Nattress, B. (2013). An overview of electronic apex locators: part 2. British Dental Journal, 214(5), 231.
dc.relationAzabal, M., García, O. D., & De la Macorra, J. C. (2004). Accuracy of the Justy II Apex locator in determining working length in simulated horizontal and vertical fractures . International Endodontic Journal. , 37(3), 177.
dc.relationBaldi, J., Victorino, F., Bernardes, R., de Moraes, I., Bramante, C., García, R., & Bernardineli, N. (2007). Influence of embedding media on the assessment of electronic apex locators. Journal Endod, 33(4), 479
dc.relationBaugh, D., & Wallace, J. (n.d.). The role of apical instrumentation in root canal treatment: a review of the literature. Journal of endodontics, 31(5), 340.
dc.relationBrito, J. M., Camilo, C. C., Moreira, J. G., Pecora, J. D., & Sousa, N. M. (2012). Effect of pre flaring and file size on the accuracy of two electronic apex locators. J Appl Oral Sci. , 20, 543.
dc.relationCuster, L. E. (1918). Exact Methods of Locating the Apical Foramen. The Journal of the National Dental Association., 5(8), 819.
dc.relationde Camargo, É. J., Zapata, R. O., Medeiros, P. L., Bramante, C. M., Bernardineli, N., Garcia, R. B., & Duarte, M. A. (2009). Influence of preflaring on the accuracy of length determination with four electronic apex locators. J Endod. , 35(9), 1302
dc.relationDominici, J., Eleazer, P., Clark, S., Staat, R., & Scheetz, J. (2001). Disinfection/sterilization of extracted teeth for dental student use. . J Dent Educ. , 65(11), 1281.
dc.relationEigtheeth. (2021, Diciembre 21). Changzhou Sifary Medical Technology Co.,Ltd.-R&D C. hangzhou Sifary Medical Technology Co.,Ltd.-R&D,manufacture,marketing and service integration (eighteeth.com)
dc.relationElAyouti, A., Hülber, J. M., Judenhofer, M. S., Connert, T., Mannheim, J. G., Löst, C., & Von, O. C. (2014). Frequency of overinstrumentation with an acceptable radiographic working length. JOE, 40(8), 1099.
dc.relationElAyouti, A., Weiger, R., & Löst, C. (2001). The ability of root ZX apex locator to reduce the frequency of overestimated radiographic working length. Journal of Endodontics, 27(1), 52.
dc.relationElAyouti, A., Weiger, R., & Löst, C. (2002). Apical constriction: location and dimensions in molars-a micro-computed tomography study. Journal of endodontics, 28(2), 119.
dc.relationEstrela, C., Couto, G. S., Bueno, M. R., Bueno, K. G., Estrela, L. R., Porto, O. C., & Diógenes, A. (2018). Apical Foramen Positio. 44(11), 1748.
dc.relationFadi, F. (2015). The Gates-Glidden bur: the search continues. Journal of the history of dentistry., 63(1).
dc.relationFerreira, I., Braga, A. C., & Pina, V. I. (2019). The Precision of Propex Pixi with Different Instruments and Coronal Preflaring Procedures. Eur Endod J. , 4(2), 75.
dc.relationFogarty, T. J., & Montgomery, S. (1991). Effect of preflaring on canal transportation. . Evaluation of ultrasonic, sonic, and conventional techniques. Comparative Study, 72(3), 350.
dc.relationGordon, M. P., & Chandler, N. P. (2004). Electronic apex locators. International journal of endodontics, 37(7), 437.
dc.relationHasegawa, K., Hzuja, H., Takei, M., Goto, N., Nihei, M., & Ohashi, M. (1986). A new method and apparatus for measuring root canal length. The Journal of Nihon University School of Dentistry, 28(2), 128.
dc.relationHuang, L. (1987). An experimental study of the principle of electronic root canal measurement. . Journal of endodontics, 13(2), 64.
dc.relationKaufman, A., Keila, S., & Yoshpe, M. (2002). Accuracy of a new apex locator: An in vitro study. Int Endod J , 35(2), 192
dc.relationKeratiotis, G., Kournetas, N., Agrafioti, A., & Kontakiotis, E. G. (2019). UA comparative evaluation of two working length determination methods. Australian Endodontic Journal, 45(3), 336.
dc.relationLeón, L. M., Cabanillas, B. D., Areal, Q. V., Martín, G. J., Jiménez, S. M., Saúco, M. J., & Segura, E. J. (2021). Influence of Coronal Preflaring on the Accuracy of Electronic Working Length Determination: Systematic Review and Meta-Analysis. J Clin Med., 10(13), 2760
dc.relationMandlik, J., Shah, N., Pawar, K., Gupta, P., Singh, S., & Shaik, S. A. (2013, July). An in vivo Evaluation of Different Methods of Working Length Determination. The Journal of Contemporary Dental Practice, 14(4), 644.
dc.relationMartins, J. N., & al., e. (2014). Clinical Efficacy of Electronic Apex Locators: Systematic . Review JOE, 40(6), 777.
dc.relationMorgental, R. D., Vier-Pelisser, F. V., Luisi, S. B., Cogo, D. M., & Kopper, P. M. (2011). Preflaring effects on the accuracy of three electronic apex locators. . Revista Odonto Ciência, 26, 335.
dc.relationNagrani, A., Sanap, A., Mategaonkar, S., Khade, S., & Krishnakumar, K. (2021). Comparative Evaluation of Preflaring Versus Non-Preflaring on the Accuracy of Electronic Apex Locators-a Systematic Review. . MAR Dental Sciences.
dc.relationNekoofar, M. H., Ghandi, M. M., Hayes, S. J., & Dummer, P. M. (2006). 3. Nekoofar M, Ghandi M , Hayes S, Dummer P. The fundamental operating principles of electronic root canal length measurement devices. . International Endodontic Journal. , 39(8), 609.
dc.relationOliveira, T., Vivacqua, G. N., Bernardes, R., Vivan, R., Duarte, M., & Vasconcelos, B. (2017). Determination of the Accuracy of 5 Electronic Apex Locators in the Function of Different Employment Protocols. Journal of Endodontics, 43(10), 1667.
dc.relationPécora, J. D., Capelli, A., Guerisoli, D. M., Spanó, J. C., & Estrela, C. (2005). Influence of cervical preflaring on apical file size determination. Int Endoj J., 38(7), 435.
dc.relationPishipati, K. V. (2013). An In Vitro Comparison of Propex II Apex Locator to Standard Radiographic Method. Iranian Endod Journal. , 8(3), 114.
dc.relationPlotino, G., Nagendrababu, V., Bukiet, F., Grande, N. M., Veettil, S. K., De-Deus, G., & Ahmed, H. M. (2020). Influence of Negotiation, Glide Path, and Preflaring Procedures on Root Canal Shaping-Terminology, Basic Concepts, and a Systematic Review. . Journal of Endodontics, 46(6), 729.
dc.relationRicucci, D., & Langeland, K. (1998). Apical limit of root canal instrumentation and obturation, part 1. Literature review. International endodontic journal, 31(6), 409.
dc.relationRoland, D., Andelin, W., Browning, D., Hsu, G., & Torabinejad, M. (2002). The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments. Journal of Endodontics, 28(7), 545.
dc.relationSaito, T., & Yamashita, Y. (1990). Electronic determination of root canal length by newly developed measuring device. Influences of the diameter of apical foramen, the size of K file and the root canal irrigants. Dentistry in Japan, 27(1), 72.
dc.relationSaritha, V., Raghu, H., Kumar, T., Totad, S., Kamatagi, L., & Saraf, P. (2021). The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study. . J Conserv Dent., 24(1), 46.
dc.relationSerna, P. G., Gomes, A. S., Flores, T. J., Madla, C. E., Rodríguez, D. I., & Martínez, G. G. (2020). Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex . Pixi. JOE. , 46(2), 161.
dc.relationSunada, I. (1962). Nuevo método para medir la longitud del conducto radicular. Revista de investigación dental, 41(2), 387.
dc.relationSuryantoro, R., Meidyawati, R., & Suprastiwi, E. (2017). The effect of coronal preflaring on the accuracy of two electronic apex locators . Journal of Physics: Serie de conferencias, 884(1).
dc.relationYamaguchi, M., Noiri, Y., Itoh, Y., Komichi, S., Yagi, K., Uemura, R., & Ebisu, S. (2018). Factors that cause endodontic failures in general practices in Japan . BMC Salud Bucal., 18(1), 5
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.titleEvaluación In Vitro de la Exactitud de los Localizadores Electrónicos de Ápice: Ifive de Denjoy ®. Airpex de Eigthteeth ®, Propex Pixi de Dentsply ® Con Relación al Pre-Ensanchamiento


Este ítem pertenece a la siguiente institución