dc.description.abstract | En la actualidad se observa viviendas en el Perú con construcciones informales en sus
azoteas con la ejecución de parapetos y alfeizares ya sea de material noble o Drywall. La
metodología de construcción en viviendas a nivel mundial es diversa, siendo algunos de
ellos contaminantes para el medio ambiente, construcciones a largos plazos y a veces
riesgosas en su tiempo de ejecución. En la construcción de parapetos y alfeizares en
azoteas se ejecutan muros exteriores con el sistema Drywall con el criterio de aligerar la
sobrecarga que se le da a la vivienda dado también que nos brinda una rápida y fácil
ejecución en obra, consecuentemente esto nos conlleva a su investigación.
Por ello se requiere obtener información de su comportamiento estructural ante una carga
perpendicular a su plano y ver los riesgos del mal uso que los maestros de obra le pueden
dar a este tipo de material por falta de conocimiento del Manual Técnico SuperBoard, ya
que se nos informó y observo que no siguen los requerimientos constructivos que nos
brinda el manual técnico. Para nuestro estudio se ejecutaron 12 prototipos de alféizares
de Drywall: 4 prototipos con placa de Drywall de 8mm, 4 prototipos con placa de Drywall
de 12mm y 4 según recomendaciones de los tesistas con ayuda y criterio de nuestro
asesor. Los prototipos fueron sometidos a una carga perpendicular a su plano con un
ensayo monotónico, lo que nos lleva a concluir y obtener la información de su
comportamiento.
Nuestros resultados obtenidos en laboratorio nos muestran el comportamiento de nuestros
muros ante cargas perpendiculares a su plano de nuestros alféizares de Drywall según la
RNE E.070 se calcula nuestros esfuerzos admisibles en tracción por flexión (dt), donde
para muros no portantes (alfeizares y parapetos) este será mayor igual a 1.50 Kg/cm2
,
teniendo muros con placas de 8mm con el criterio del maestro de obra se obtuvo 0.72
Kg/cm2
, para muros con placas de 12 mm se obtuvo 1.73 Kg/cm2
y para nuestra propuesta
de diseño con placas de 8mm + refuerzo se obtuvo 1.82 Kg/cm2
.
Concluyendo que se debe cumplir las especificaciones indicadas en el manual técnico
SuperBoard ya que nuestros prototipos #1 no cumplen con lo requerido en la RNE E.070,
lo cual se podrá observar con más detalle en los cálculos de gabinete | |
dc.description.abstract | Currently, houses in Peru are observed with informal constructions on their roofs with the
execution of parapets and sills, whether of noble material or Drywall. The methodology
of construction in homes worldwide is diverse, some of them being polluting for the
environment, long-term construction and sometimes risky in its execution time. In the
construction of parapets and sills on roofs, external walls are executed with the Drywall
system with the criterion of lightening the overload that is given to the house since it also
gives us a quick and easy execution on site, consequently this leads to its investigation.
For this reason, it is required to obtain information on its structural behavior in the face
of a load perpendicular to its plane and to see the risks of misuse that construction masters
can give to this type of material due to lack of knowledge of the SuperBoard Technical
Manual, since we are informed and I observe that they do not follow the constructive
requirements that the technical manual provides us. For our study, 12 prototypes of
Drywall sills were executed: 4 prototypes with 8mm Drywall plate, 4 prototypes with
12mm Drywall plate and 4 according to the thesis recommendations with the help and
judgment of our advisor. The prototypes were subjected to a load perpendicular to their
plane with a monotonic test, which leads us to conclude and obtain information on their
behavior.
Our results obtained in the laboratory show us the behavior of our walls before loads
perpendicular to their plane of our Drywall windowsills according to RNE E.070, our
admissible stresses in flexural traction (dt) are calculated, where for non-bearing walls
(sills and parapets) this will not be greater than 1.50 Kg / cm2, having walls with 8mm
plates with the criterion of the master builder 0.72 Kg / cm2 was obtained, for walls with
12mm plates 1.73 Kg / cm2 was obtained and for our proposal of design with 8mm plates
+ reinforcement, 1.82 Kg / cm2 was obtained.
Concluding that the specifications indicated in the SuperBoard technical manual must be
met since our # 1 prototypes do not meet the requirements of RNE E.070, which can be
observed in more detail in the cabinet calculations. | |
dc.language | spa | |
dc.publisher | Universidad Privada Antenor Orrego | |
dc.publisher | PE | |
dc.relation | T_ING.CIVIL_1869 | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.source | Universidad Privada Antenor Orrego | |
dc.source | Repositorio institucional - UPAO | |
dc.subject | Drywall | |
dc.subject | Cargas | |
dc.title | Comportamiento de alféizares de drywall reforzados sometido a cargas perpendiculares a su plano | |
dc.type | info:eu-repo/semantics/bachelorThesis | |