dc.creatorAbafogi, Abdurhaman Teyib
dc.creatorKim, Jaewon
dc.creatorLee, Jinyeop
dc.creatorMohammed, Merem Omer
dc.creatorvan Noort, Danny
dc.creatorPark, Sungsu
dc.date.accessioned2021-03-16T23:23:01Z
dc.date.available2021-03-16T23:23:01Z
dc.date.created2021-03-16T23:23:01Z
dc.date.issued2020-02-21
dc.identifier1424-8220
dc.identifierhttps://hdl.handle.net/20.500.12815/193
dc.identifierhttps://doi.org/10.3390/s20041202
dc.identifierSensors
dc.description.abstractMolecular diagnostics for sepsis is still a challenge due to the presence of compounds that interfere with gene amplification and bacteria at concentrations lower than the limit of detection (LOD). Here, we report on the development of a 3D printed modular microfluidic device (3DpmµFD) that preconcentrates bacteria of interest in whole blood and purifies their genomic DNA (gDNA). It is composed of a W-shaped microchannel and a conical microchamber. Bacteria of interest are magnetically captured from blood in the device with antibody conjugated magnetic nanoparticles (Ab-MNPs) at 5 mL/min in the W-shaped microchannel, while purified gDNA of the preconcentrated bacteria is obtained with magnetic silica beads (MSBs) at 2 mL/min in the conical microchamber. The conical microchamber was designed to be connected to the microchannel after the capturing process using a 3D-printed rotary valve to minimize the exposure of the MSBs to interfering compounds in blood. The pretreatment process of spiked blood (2.5 mL) can be effectively completed within about 50 min. With the 3DpmµFD, the LOD for the target microorganism Escherichia coli O157:H7 measured by both polymerase chain reaction (PCR) with electrophoresis and quantitative PCR was 10 colony forming unit (CFU) per mL of whole blood. The results suggest that our method lowers the LOD of molecular diagnostics for pathogens in blood by providing bacterial gDNA at high purity and concentration.
dc.languageeng
dc.publisherMDPI
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceRepositorio Institucional UTEC
dc.sourceUniversidad de Ingeniería y Tecnología - UTEC
dc.subjectMolecular diagnostics
dc.subjectMicrofluidic device
dc.subjectBacterial preconcentration
dc.subjectDNA purification
dc.subjectPathogen
dc.title3D-printed modular microfluidic device enabling preconcentrating bacteria and purifying bacterial DNA in blood for improving the sensitivity of molecular diagnostics
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución