dc.creatorAlvarez-Mendoza, Cristhoper
dc.creatorVilchez-Lucana, Jhon
dc.creatorSierra-Liñan, Fernando
dc.creatorCabanillas-Carbonell, Michael
dc.date.accessioned2022-05-02T14:46:38Z
dc.date.accessioned2023-05-30T23:10:24Z
dc.date.available2022-05-02T14:46:38Z
dc.date.available2023-05-30T23:10:24Z
dc.date.created2022-05-02T14:46:38Z
dc.date.issued2022
dc.identifierAlvarez-Mendoza, C., Vilchez-Lucana, J., Sierra-Liñan, F., & Cabanillas-Carbonell, M. (2022). Free Hardware based System for Air Quality and CO2 Monitoring. International Journal of Advanced Computer Science and Applications, 13(2).
dc.identifier2156-5570
dc.identifierhttps://hdl.handle.net/20.500.13067/1827
dc.identifierInternational Journal of Advanced Computer Science and Applications
dc.identifierhttps://doi.org/10.14569/IJACSA.2022.0130244
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6472620
dc.description.abstractDue to the increase in air pollution, especially in Latin American countries of low and middle income, great environmental and health risks have been generated, highlighting that there is more pollution in closed environments. Given this problem, it has been proposed to develop a system based on free hardware for monitoring air quality and CO2, in order to reduce the levels of air pollution in a closed environment, improving the quality of life of people and contributing to the awareness of the damage caused to the environment by the hand of man himself. The system is based on V-Model, complemented with a ventilation prototype implemented with sensors and an application for its respective monitoring. The sample collected in the present investigation was non-probabilistic, derived from the reports of air indicators during 15 days with specific schedules of 9am, 1pm and 6pm. The results obtained indicated that the air quality decreased to 670 ppm, as well as the collection time decreased to 5 seconds and finally the presence of CO2 was reduced to 650 ppm after the implementation of the system, achieving to be within the standards recommended by the World Health Organization.
dc.languageeng
dc.publisherThe Science and Information Organization
dc.publisherPE
dc.relationhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85126087998&doi=10.14569%2fIJACSA.2022.0130244&partnerID=40&md5
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceAUTONOMA
dc.source13
dc.source2
dc.source377
dc.source384
dc.subjectAir quality
dc.subjectAir pollution
dc.subjectCO2
dc.subjectControl system
dc.subjectFree hardware
dc.subjectV-model
dc.titleFree Hardware based System for Air Quality and CO2 Monitoring
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución