dc.creatorCustodio López, Jesús J.
dc.date.accessioned2023-03-21T20:25:25Z
dc.date.accessioned2023-05-30T21:19:06Z
dc.date.available2023-03-21T20:25:25Z
dc.date.available2023-05-30T21:19:06Z
dc.date.created2023-03-21T20:25:25Z
dc.date.issued2023-01
dc.identifierCirugía Cardiovascular . 2023;30(1).
dc.identifier1134-0096
dc.identifierhttps://hdl.handle.net/20.500.12959/3483
dc.identifierhttps://doi.org/10.1016/j.circv.2022.06.002
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6451323
dc.description.abstractReportamos el caso de una embolización espontánea del disco mecánico de una prótesis aórtica monodisco 4 años después de su implante. El motivo del implante fue una endocarditis bacteriana. El paciente ingresó con disnea y edema pulmonar severo debido a la insuficiencia aórtica, que demandó una cirugía inmediata de recambio de prótesis. El cateterismo cardiaco reveló la ausencia del disco, lo que se confirmó intraoperatoriamente. Controles radiográficos postoperatorios demostraron que el disco se encontraba incrustado en el centro del eje longitudinal de la ilíaca izquierda, sin producir obstrucción al flujo de la sangre. El disco nunca fue retirado. El paciente se mantuvo sin síntomas vasculares durante 11 años. Falleció debido a una gangrena de Fornier complicada con Covid-19.
dc.description.abstractWe report the case of spontaneous disc embolization of a mechanical aortic prosthesis 4 years after its implantation. The reason for the implant was due to bacterial endocarditis. The patient was admitted with dyspnea and severe pulmonary edema due to aortic insufficiency that required immediate prosthesis replacement surgery. Cardiac catheterization revealed the absence of the disc, which was confirmed intraoperatively. Postoperative radiographic controls showed that the disc was embedded in the center of the longitudinal axis of the left iliac without causing obstruction to blood flow. The disc was never removed. The patient remained asymptomatic without vascular sym ptoms for 15 years. He died due to Fornier's gangrene complicated by Covid-19.
dc.languagespa
dc.publisherSociedad Española de Cirugía Cardiovascular y Endovascular (SECCE)
dc.relationhttps://www.sciencedirect.com/science/article/pii/S1134009622001346
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEmbolización de valva
dc.subjectPrótesis cardiaca
dc.subjectFalla valvular
dc.subjectCuerpo extraño intravascular
dc.subjectReemplazo valvular aórtico
dc.subjectLeaflet embolization
dc.subjectProsthetic heart valve
dc.subjectValve failure
dc.subjectIntravascular foreign body
dc.subjectAortic valve replacement
dc.titleEmbolización espontánea del disco de prótesis aórtica: caso clínico
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución