dc.contributorSagastegui Vásquez, German
dc.creatorHernandez Rodriguez, Jasmin Yahira
dc.creatorVaca Rodriguez, John Jorginho
dc.date.accessioned2023-05-16T19:56:40Z
dc.date.accessioned2023-05-23T13:11:04Z
dc.date.available2023-05-16T19:56:40Z
dc.date.available2023-05-23T13:11:04Z
dc.date.created2023-05-16T19:56:40Z
dc.date.issued2023-03-21
dc.identifierHernandez, J. Y., & Vaca, J. J. (2022). Influencia de la adición de viruta de acero en la resistencia a compresión en ladrillos artesanales en prismas de albañilería, Trujillo, 2022 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/33405
dc.identifier620.1124 HERN/I 2022
dc.identifierhttps://hdl.handle.net/11537/33405
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6381953
dc.description.abstractEsta investigación tiene como objetivo determinar la influencia de la adición de viruta de acero (V.A.) en la resistencia a compresión de ladrillos artesanales en prismas de albañilería, por lo que se elaboraron 30 prismas, cada prisma conformado por tres ladrillos y una junta de 1,5 cm, 6 de estos por cada porcentaje que fue de 0 %, 5 %, 10 %, 15 % y 20 % de adición de viruta de acero. La investigación es experimental y según su naturaleza es cuantitativa. Los resultados indican que para una adición de 15 % (V.A.), la resistencia a compresión en unidades de ladrillos aumenta y es óptima, teniendo como resultado un 72,68 kg/cm² a diferencia del ladrillo patrón que es de 52,35 kg/cm²; en prismas sucede lo mismo para una adición de 15 % (V.A.) la resistencia a compresión llega a 48,10 kg/cm² a diferencia del prisma patrón que es de 21,21 kg/cm², sin embargo, si se adiciona a más de este porcentaje las resistencias empiezan a bajar. Se concluyó que la influencia de la adición de (V.A.) en ladrillos artesanales y prismas de albañilería influye positivamente mejorando esta propiedad en un 126,78 % con respecto a los prismas patrón, pero hasta el 15 % de adición de (V.A.).
dc.description.abstractThis research aims to determine the influence of the addition of steel shavings (VA) on the compressive strength of artisanal bricks in masonry prisms, for which 30 prisms were made, each prism made up of three bricks and a 1-inch joint. .5 cm, 6 of these for each percentage that was 0 %, 5 %, 10 %, 15 % and 20 % addition of steel wool. The research is experimental and according to its nature it is quantitative. The results indicate that for an addition of 15 % (V.A.), the compressive strength in brick units increases and is optimal, resulting in 72.68 kg/cm², unlike the standard brick, which is 52.35 kg/ cm²; In prisms the same thing happens for an addition of 15 % (V.A.) the compressive strength reaches 48.10 kg/cm² unlike the standard prism which is 21.21 kg/cm², however, if it is added to more than At this percentage the resistances begin to drop. It was concluded that the influence of the addition of (V.A.) in handmade bricks and masonry prisms has a positive influence, improving this property by 126.78 % with respect to the standard prisms, but up to 15 % of addition of (V.A.).
dc.languagespa
dc.publisherUniversidad Privada del Norte
dc.publisherPE
dc.relation9%
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.sourceUniversidad Privada del Norte
dc.sourceRepositorio Institucional - UPN
dc.subjectResistencia a la compresión
dc.subjectLadrillo
dc.subjectAlbañilería
dc.subjectResistencia de materiales
dc.subjectConstrucción
dc.subjectAcero
dc.subjectCompressive strength
dc.subjectSteel chip
dc.subjectPrisms
dc.titleInfluencia de la adición de viruta de acero en la resistencia a compresión en ladrillos artesanales en prismas de albañilería, Trujillo, 2022
dc.typeinfo:eu-repo/semantics/bachelorThesis


Este ítem pertenece a la siguiente institución