dc.description.abstractEl presente proyecto de titulación evalúa el desempeño, ante la acción sísmica, del Edificio San Francisco 300 que cuenta con 27 pisos destinados a departamentos, oficinas y áreas de parqueo. Se realizó una inspección visual con la metodología FEMA 154, se obtuvo que era necesario realizar un análisis más detallado para determinar el comportamiento de la estructura ante un evento sísmico. En el análisis modal espectral se determinaron las derivas de entrepiso, los modos de vibración y el periodo fundamental de la estructura por medio de la NEC-15, siendo la dirección “Y” la más crítica con una deriva de 0.0255. Por medio del análisis estático no lineal Pushover aplicado a pórticos representativos, se determinaron los niveles de desempeño para el Sismo Frecuente, Ocasional y Raro, dando como resultado que la dirección “Y” es la más crítica y la edificación presenta un comportamiento de incursión en el rango inelástico no deseado
dc.description.abstractThis degree project evaluates the performance, under seismic action, of the San Francisco 300 Building, which has 27 floors for apartments, offices, and parking areas. A visual inspection was carried out with the FEMA 154 methodology, and it was found that a more detailed analysis was necessary to determine the behavior of the structure in a seismic event. In the spectral modal analysis, the inter-story drifts, the vibration modes, and the fundamental period of the structure were determined by means of the NEC-15, being the "Y" direction the most critical with a drift of 0.0255. By means of the Pushover nonlinear static analysis applied to representative frames, the performance levels for the Frequent, Occasional and Rare Earthquake were determined, resulting that the "Y" direction is the most critical and the building presents a behavior of incursion in the undesired inelastic range
dc.languagespa
dc.publisherUniversidad de Guayaquil - Facultad de Ciencias Matemáticas y Físicas Carrera de Ingeniería Civil
dc.rightsopenAccess
dc.subjectSismo
dc.subjectDesempeño
dc.subjectPushover
dc.subjectRótulas
dc.subjectModal
dc.titleEvaluación de la capacidad y desempeño estructural de una edificación de 27 pisos ubicada en Guayaquil, mediante el análisis no lineal Pushover
dc.typeThesis