dc.creatorAtria, Pablo J
dc.creatorAbad Coronel, Cristian Gustavo
dc.creatorBlatz, Markus
dc.creatorPendola, Martin
dc.creatorMena Cordova, Nancy Cecilia
dc.creatorCornejo, Julián
dc.creatorRomero Muñoz, Carla Estefania
dc.date.accessioned2022-12-06T13:29:16Z
dc.date.accessioned2023-05-22T16:46:40Z
dc.date.available2022-12-06T13:29:16Z
dc.date.available2023-05-22T16:46:40Z
dc.date.created2022-12-06T13:29:16Z
dc.date.issued2022
dc.identifier1708-8240
dc.identifierhttp://dspace.ucuenca.edu.ec/handle/123456789/40425
dc.identifierhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85125571393&doi=10.1111%2fjerd.12889&partnerID=40&md5=25fe91e996e13b626e50ba364764fd40
dc.identifier10.1111/jerd.12889
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6326995
dc.description.abstractObjectives: This study aimed to provide information on the accuracy of exported digital files with the different resolutions available in the CEREC 4.6.2 software obtained by means of an intraoral scanner (IOS), in addition to establishing differences between materialized models with different exported resolutions, and how these different exported files can influence finite element analysis (FEA) simulations. Materials and Methods: The upper complete arch of 10 patients was scanned through an IOS (CEREC Omnicam 1.0/Dentsply Sirona). Files of three resolution meshes digitalized by a CAD software (Cerec SW, 4.6.2) high, medium and low (IOSH, IOSM, and IOSL) were exported. Each file was evaluated by a software (NETFABB) about the number of triangles obtained and compared with the number announced by the manufacturer. Also, with a superimposition with a specialized software (GEOMAGIC X), the digital models were compared. The files of each resolution were printed (Sprintray 3D Printer), and the printed models were scanned with IOS (Omnicam 1.0) and compared with the control group (intraoral scanned high-resolution file, IOSH). FEA simulations were imported into COMSOL and analyzed under different loading conditions. Results: The number of exported triangles coincided with that reported by the manufacturer. The digital models from files of different resolution did not show significant differences (less than 1.5 um) between each other. Models printed (H, M, L) from files of the same resolution mesh (H, M, L) did not show significant differences between them either in partial measures of the arch and neither in the complete arch. FEA showed significant differences in stress concentration between different exported models. Clinical Significance: Digital models can be exported and printed in three resolutions of the mesh, without differences clinically significative. On the other hand, for future FEA applications further research should be performed in order to determine the optimal number of triangles.
dc.languagees_ES
dc.sourceJournal of Esthetic and Restorative Dentistry
dc.subjectDental materials
dc.subjectCAD CAM
dc.subjectDigital dentistry
dc.titleAnalysis of the mesh resolution of an .STL exported from an intraoral scanner file
dc.typeARTÍCULO