dc.description.abstract | El presente trabajo de titulación tiene como objetivo obtener el punto de desempeño de la edificación, a través de la aplicación del análisis no lineal: estática Pushover. Primero evaluando elementos estructurales existentes con base a los criterios sismo resistentes dados por la NEC-SE-DS. Se realizó el análisis modal espectral obteniendo un periodo de vibración de 0.46 segundos. Con el análisis no lineal estático Pushover para un sismo de diseño (raro) el punto de desempeño se encuentra entre el rango de seguridad de vida y el colapso de la curva de capacidad. La dirección más crítica es el sentido Y con una deriva de 0.016. Se concluye que la edificación no tendrá un buen comportamiento frente a un sismo de diseño y si no se aplica los reforzamientos requeridos la estructura podria colapsar | |
dc.description.abstract | The objective of this degree work is to obtain the performance point of the building, through the application of the nonlinear analysis: Pushover statics. First, by evaluating existing structural elements based on the seismic resistant criteria given by the NEC- SE-DS. The spectral modal analysis was performed, obtaining a vibration period of 0.46 seconds. With the nonlinear static Pushover analysis for a design earthquake (rare) the performance point is between the life safety range and the collapse of the capacity curve. The most critical direction is the Y direction with a drift of 0.016. It is concluded that the building will not perform well in a design earthquake and if the required reinforcements are not applied, the structure could collapse. | |
dc.language | spa | |
dc.publisher | Universidad de Guayaquil - Facultad de Ciencias Matemáticas y Físicas - Carrera de Ingeniería Civil | |
dc.relation | ;1 Digital | |
dc.rights | openAccess | |
dc.subject | DESEMPEÑO | |
dc.subject | SISMO | |
dc.subject | PUSHOVER | |
dc.subject | RÓTULAS | |
dc.title | Respuesta estructural de Edificio con baja ductilidad en zona de alta Sismicidad, en la ciudad de Guayaquil | |
dc.type | bachelorThesis |