dc.contributor | Universidade Estadual Paulista (UNESP) | |
dc.contributor | Instituto de Biociências | |
dc.contributor | Núcleo de Atividade Física Esporte Saúde NAFES | |
dc.date.accessioned | 2022-04-29T09:23:55Z | |
dc.date.accessioned | 2022-12-20T03:25:39Z | |
dc.date.available | 2022-04-29T09:23:55Z | |
dc.date.available | 2022-12-20T03:25:39Z | |
dc.date.created | 2022-04-29T09:23:55Z | |
dc.date.issued | 2008-12-01 | |
dc.identifier | Revista Brasileira de Cineantropometria e Desempenho Humano, v. 10, n. 3, p. 289-293, 2008. | |
dc.identifier | 1415-8426 | |
dc.identifier | 1980-0037 | |
dc.identifier | http://hdl.handle.net/11449/232233 | |
dc.identifier | 10.5007/1980-0037.2008v10n3p289 | |
dc.identifier | 2-s2.0-84893839177 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/5412368 | |
dc.description.abstract | Incremental tests are commonly used to predict metabolic responses during square-wave mode exercises. However, in some cases the predicted and observed results may be not similar. Main objective: To verify the hypothesis that, at certain intensities in the severe domain, VO2 determined during the incremental test is lower than that observed at these workloads using the square-wave test. Methodological proceedings: Eight physically active males (21.5 ± 4 years, 73.7 ± 5.3 kg and 180.8 ± 4.1 cm) performed: 1) an incremental test on cycle ergometer to determine the VO2 of the intensities (VO2INC); 2) a square-wave test at three severe intensities (Light (L), Medium (M) and Heavy (H) to determine the critical power (CP) and to compare the VO2 (VO2RET) observed with the VO2INC;3) a square-wave test at CP intensity to compare the time response of VO2 with P, M and L, at four different sample times. Results: The VO2INCat L intensity underestimated the VO2RET(3.2 ± 0.5 vs. 3.8 ± 0.6 l.min-1). No differences were observed at the other intensities (M: 3.5 ± 0.5 vs. 3.6 ± 0.5 l.min-1; H: 3.7 ± 0.5 vs. 3.4 ± 0.6 l.min-1; CP: 2.7 ± 0.5 vs. 3.0 ± 0.6 l.min-1). The VO2 at CP was lower at all times, exhibited a steady state and did not achieve VO2max. Initially, at L intensity, the VO2 was smaller than its pairs. However, at the last sample time, it achieved VO2max and became equal to the other severe intensities. Conclusion: The incremental test underestimates the VO2 observed at lighter intensities within the severe domain. | |
dc.language | eng | |
dc.language | por | |
dc.relation | Revista Brasileira de Cineantropometria e Desempenho Humano | |
dc.source | Scopus | |
dc.subject | Constant power | |
dc.subject | Oxygen uptake | |
dc.subject | Progressive test | |
dc.subject | Severe domain | |
dc.title | Consumo de oxigênio no domínio de intensidade severo durante teste incremental e retangular | |
dc.type | Artículos de revistas | |