Determinação de Mercúrio Lábil em Amostras de Sólidos Totais SuspensosemÁguasNaturaisporAnáliseDiretaporDecomposição TérmicacomparandoviaEspectrometriadeFluorescênciaAtômica de Vapor Frio

dc.contributorPrograma de Pós Graduação em Química
dc.contributorInstituto Nacional de Pesquisas da Amazônia
dc.contributorServiço Geológico do Brasil
dc.contributorUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:29:07Z
dc.date.accessioned2022-12-20T02:44:33Z
dc.date.available2022-04-29T08:29:07Z
dc.date.available2022-12-20T02:44:33Z
dc.date.created2022-04-29T08:29:07Z
dc.date.issued2020-11-01
dc.identifierRevista Virtual de Quimica, v. 12, n. 6, p. 1398-1410, 2020.
dc.identifier1984-6835
dc.identifierhttp://hdl.handle.net/11449/228886
dc.identifier10.21577/1984-6835.20200108
dc.identifier2-s2.0-85099153258
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5409020
dc.description.abstractThis work presents the validation of an analytical method for determining the lip fraction of Hg in water bottles. One proposal was reduced in reducing the temperature of glass fiber glass filters (0.7 μm GF / F), so that there was no loss of Hg. After the digestion step with concentrated HNO3 (EPA 3051a), as HgL determinations were performed by the direct mercury analyst (DMA), confirm by the comparative method of steam vapor atomic fluorescence spectrometry (CV-AFS). A concentration of HgL applied by the DMA technique ranged from 0.044 to 0.145 ng mL-1, while CV-AFS varied from 0.002 to 0.138 ng mL-1. Regarding recovery, the results obtained for both methods were 113.6% and 107.0%, respectively. An analysis of the results showed that there was no statistically significant difference (p <0.05), showing good accuracy of the technical proposal. The evaluation of the displayed response surface, which measures the total content (TSS), increases, the HgL concentration also increases. ANOVA showed statistical significance when the independent variables were correlated with the content of the TSS (95% level). Thus, as the analyzes that determine the determination of HgL in the TSS of river water are possible via DMA, as long as the boundary conditions (temperature control and cleaning of glassware) are followed.
dc.languagepor
dc.relationRevista Virtual de Quimica
dc.sourceScopus
dc.subjectAnalytical validation
dc.subjectLabile mercury
dc.subjectSuspended solids
dc.titleDetermination of Labile Mercury in Impressions of Total Solids Suspended in Natural Waters by Direct Analysis by Thermal Decomposition Comparing via Cold Steam Atomic Fluorescence Spectrometry
dc.titleDeterminação de Mercúrio Lábil em Amostras de Sólidos Totais SuspensosemÁguasNaturaisporAnáliseDiretaporDecomposição TérmicacomparandoviaEspectrometriadeFluorescênciaAtômica de Vapor Frio
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución