dc.contributorCMEMS-UMinho – Center of MicroElectroMechanical Systems – Universidade do Minho
dc.contributorDEMM – Department of Metallurgical and Materials Engineering – Faculdade de Engenharia da Universidade do Porto
dc.contributorAzurém
dc.contributorUniversidade Estadual Paulista (UNESP)
dc.contributorTribocorrosion and Nanomedicine
dc.contributorR. Dr. Xavier Sigaud
dc.contributorUniversidade do Grande Rio
dc.contributorInstitute of Science and Innovation in Mechanical and Industrial Engineering
dc.contributorIzmir Institute of Technology
dc.contributorUniversidade Federal do Rio de Janeiro (UFRJ)
dc.date.accessioned2022-04-28T19:48:11Z
dc.date.accessioned2022-12-20T01:31:48Z
dc.date.available2022-04-28T19:48:11Z
dc.date.available2022-12-20T01:31:48Z
dc.date.created2022-04-28T19:48:11Z
dc.date.issued2022-03-10
dc.identifierJournal of Alloys and Compounds, v. 896.
dc.identifier0925-8388
dc.identifierhttp://hdl.handle.net/11449/223014
dc.identifier10.1016/j.jallcom.2021.162965
dc.identifier2-s2.0-85120888579
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5403143
dc.description.abstractPoor tribocorrosion resistance of Ti and its alloys remains as a concern for load-bearing biomedical implants. Despite being an effective method to improve tribocorrosion resistance, titanium matrix composites (TMCs) have yet to be used in this type of applications. In-situ TiB (titanium boride) and TiC (titanium carbide) reinforcement phases have been considered as one of the best options to produce TMCs once these phases present high compatibility and strong interfacial bonding with Ti. Although the effect of these phases on the mechanical properties of Ti has been thoroughly researched in the last years, their effect on corrosion, tribocorrosion and biocompatibility of Ti is yet to be fully understood. In this work, in-situ Ti-TiB-TiCx composites obtained by reactive hot pressing showed identical corrosion response compared to the unreinforced Ti but displayed improved tribocorrosion behaviour. Under 0.5 N load, composites presented as average a reduction of 51% in wear volume loss and under 10 N the reduction was up to 93%. Early biological tests showed promising results, as composites were biocompatible and induced osteoblasts spreading and possibly proliferation most probably due to composite chemistry and surface hardness.
dc.languageeng
dc.relationJournal of Alloys and Compounds
dc.sourceScopus
dc.subjectCorrosion
dc.subjectLoad-bearing implants
dc.subjectOsteoblasts
dc.subjectTitanium matrix composites
dc.subjectTribocorrosion
dc.titlePreliminary tribo-electrochemical and biological responses of the Ti-TiB-TiCx in-situ composites intended for load-bearing biomedical implants
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución