dc.contributor | Nishioka, Renato Sussumu [UNESP] | |
dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2021-10-21T15:48:47Z | |
dc.date.accessioned | 2022-12-19T23:54:39Z | |
dc.date.available | 2021-10-21T15:48:47Z | |
dc.date.available | 2022-12-19T23:54:39Z | |
dc.date.created | 2021-10-21T15:48:47Z | |
dc.date.issued | 2021-08-12 | |
dc.identifier | http://hdl.handle.net/11449/214830 | |
dc.identifier | 33004145070P8 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/5395133 | |
dc.description.abstract | Este estudo teve como objetivo analisar a microdeformação ao redor de implantes, geradas por cargas não axiais estáticas, em pilares protéticos minipilar e cônico (CMN) em prótese múltipla de três elementos, por meio da extensometria. Foram confeccionados dez blocos em poliuretano para cada grupo avaliado (n=20). Cada bloco recebeu três implantes na configuração “off set”, seus respectivos pilares protéticos (CMN ou minipilar) e uma prótese múltipla de três elementos (n=20). Foram colados quatro extensômetros na superfície de cada bloco tangenciando cada implante para a realização dos ensaios. Para cada bloco foi fundida uma prótese múltipla de três elementos em Liga NiCr (n=20). Foi utilizado um dispositivo de aplicação de cargas com carga de 30 kgf sobre os pontos C, D, E e F durante 10 segundos, sob três repetições, seguindo um esquema fatorial de: 2 x 3. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste t em duas amostras em par para médias (p<0,05). No minipilar a maior média de microdeformação (1369,68με) foi observada no extensômetro 4 (EG4), quando aplicada carga no ponto de aplicação F. Enquanto que a menor média de microdeformação (473,29 με) foi observada no extensômetro 3 (EG3), quando aplicada carga no ponto de aplicação C. Já no pilar CNM, a maior média de microdeformação (1418,64με) foi observada no extensômetro 4 (EG4), quando aplicada carga no ponto de aplicação F enquanto a menor média de microdeformação (550,53 με) foi observada no extensômetro 1 (EG1), quando aplicada carga no ponto de aplicação C. O estudo concluiu que os pilares CMN apresentaram comportamento biomecânico compatíveis aos minipilares. Portanto, o componente não axial do pilar CMN parece não contraindicar sua utilização suportando próteses múltiplas. | |
dc.description.abstract | This study aimed to analyze the microdeformation around implants, generated by static non-axial loads, in mini-pillar and conical prosthetic abutments (CMN) in multiple three-element prosthesis, by means of extensometry. Ten blocks in polyurethane were made for each group evaluated (n=20). Each block received three implants in the “off set” configuration, their respective prosthetic pillars (CMN or minipillar) and a multiple three-element prosthesis (n=20). Four strain gauges were glued on the surface of each block, tangent to each implant, to carry out the tests. For each block, a three-element multiple prosthesis in NiCr Alloy (n=20) was cast. A load application device with a load of 30 kgf was used on points C, D, E and F for 10 seconds, under three repetitions, following a factorial scheme of: 2 x 3. The data obtained were statistically analyzed using the test Two-way RM ANOVA and t-test on two paired samples for means (p<0.05). In the mini-pillar, the highest mean microstrain (1369.68με) was observed in strain gauge 4 (EG4), when load was applied at application point F. While the lowest mean microstrain (473.29 με) was observed in strain gauge 3 (EG3 ), when load was applied at application point C. On the CNM abutment, the highest mean microstrain (1418.64με) was observed in strain gauge 4 (EG4), when load was applied at application point F, while the lowest microstrain mean ( 550.53 με) was observed in strain gauge 1 (EG1), when load was applied at application point C. The study concluded that CMN abutments presented biomechanical behavior compatible with mini-pillars. Therefore, the non-axial component of the CMN abutment does not seem to contraindicate its use when supporting multiple prostheses. | |
dc.language | por | |
dc.publisher | Universidade Estadual Paulista (Unesp) | |
dc.rights | Acesso aberto | |
dc.subject | Implantes dentários | |
dc.subject | Fenômenos biomecânicos | |
dc.subject | Prótese dentária | |
dc.subject | Teste de materiais | |
dc.subject | Dental implants | |
dc.subject | Biomechanical phenomena | |
dc.subject | Dental prosthesis | |
dc.subject | Test materials | |
dc.title | Estudo biomecânico das microdeformações ao redor de pilares protéticos para próteses multíplas sob carregamento não axial estático | |
dc.type | Tesis | |