dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniv Fed Rio Grande do Sul
dc.date.accessioned2021-06-25T15:03:48Z
dc.date.accessioned2022-12-19T23:03:00Z
dc.date.available2021-06-25T15:03:48Z
dc.date.available2022-12-19T23:03:00Z
dc.date.created2021-06-25T15:03:48Z
dc.date.issued2021-05-01
dc.identifierJournal Of The Brazilian Society Of Mechanical Sciences And Engineering. Heidelberg: Springer Heidelberg, v. 43, n. 5, 17 p., 2021.
dc.identifier1678-5878
dc.identifierhttp://hdl.handle.net/11449/210288
dc.identifier10.1007/s40430-021-02999-2
dc.identifierWOS:000645913100001
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5390888
dc.description.abstractNon-Newtonian fluids are commonly seen in industrial processes, such as those of the oil and mining industry, and in natural flows, like dam ruptures, landslides or mud flows. The hydrodynamic modeling of such processes/phenomena is directly linked to the rheological properties of the flowing fluid, usually characterized through rheometers. The high cost of rheometers and possible inaccessibility for certain applications demand for research of alternative rheometric methods. In order to assess the problem, the present work discusses a detailed experimental methodology to evaluate if the steady and uniform flow in an inclined channel is able to produce the flow curve for the test fluid carbopol 996 gel and work as an alternative rheometer. In order to estimate the shear rates and shear stresses, we measured the normal depth (ultrasonic technique), specific discharge (manual gravimetric method) and free surface velocity (manually and with laser barrier sensors). Based on the theoretical solutions, a simplified fitting procedure was adopted to make possible the assessment of shear rate and shear stress through the experimental data. The obtained flow curves were then compared with the reference flow curve, determined by a commercial R/S rheometer. Results showed that the experimental methods were able to provide the flow curves within acceptable uncertainty and the defined methodology detailed in the work can estimate satisfactorily the flow curve of non-Newtonian fluids. Finally, we highlighted that the wide channel hypothesis is the strongest condition to be guaranteed in order to obtain precise flow curves through the methodology present in this work.
dc.languageeng
dc.publisherSpringer
dc.relationJournal Of The Brazilian Society Of Mechanical Sciences And Engineering
dc.sourceWeb of Science
dc.subjectFlow curve determination
dc.subjectRheometry
dc.subjectNon-newtonian fluids
dc.subjectInclined open-channel
dc.subjectExperimental method
dc.titleObtaining flow curve for viscoplastic fluids through inclined open-channel apparatus
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución