dc.contributorFed Fluminense Univ UFF
dc.contributorUniv Salgado de Oliveira
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorFed Inst Educ Sci & Technol Mato Grosso do Sul
dc.contributorUniv Fed Juiz de Fora
dc.date.accessioned2020-12-11T14:56:10Z
dc.date.accessioned2022-12-19T20:32:36Z
dc.date.available2020-12-11T14:56:10Z
dc.date.available2022-12-19T20:32:36Z
dc.date.created2020-12-11T14:56:10Z
dc.date.issued2020-04-15
dc.identifierIeee Sensors Journal. Piscataway: Ieee-inst Electrical Electronics Engineers Inc, v. 20, n. 8, p. 4221-4228, 2020.
dc.identifier1530-437X
dc.identifierhttp://hdl.handle.net/11449/197722
dc.identifier10.1109/JSEN.2019.2961934
dc.identifierWOS:000522206500028
dc.identifier2883440351895167
dc.identifier0000-0001-6320-755X
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5378360
dc.description.abstractIn this paper a new method for the detection of optical phase in passive homodyne interferometers, with high accuracy and wide dynamic range is presented. Unlike the traditional and more recent methods, which use between 3 and 6 harmonic components to calculate the modulation index, the proposed method uses only 2 harmonic components. Because of this, the method has higher accuracy in the presence of noise compared to other methods known in the literature. Further, the method has the advantage of not requiring knowledge of the phase of the excitation signal. The numerical implementation is simple, since it uses a 3rd order polynomial fit for the calculation of the modulation index. For the experimental verification of the method, a configuration based on an unbalanced Mach-Zehnder interferometer (MZI) was used, which resulted in a dynamic range for the modulation index from 8.38 to 16.76 rad. It is important to note that these limits can be easily expanded by means of adaptations of the optical and electronic setup depending on the characteristics of the excitation signal. The proposed method can be used in several applications, such as pressure measurements, vibration, displacement, etc.
dc.languageeng
dc.publisherIeee-inst Electrical Electronics Engineers Inc
dc.relationIeee Sensors Journal
dc.sourceWeb of Science
dc.subjectPassive homodyne interferometers
dc.subjectoptical phase detection method
dc.subjecthigh accuracy
dc.subjectwide dynamic range
dc.titleHigh Accuracy Homodyne Interferometric Method for Wide Dynamic Range Applications
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución