dc.contributorFed Inst Educ Sci & Technol Sao Paulo
dc.contributorFed Univ Rio Grande
dc.contributorUniv Fed Itajuba
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal de São Carlos (UFSCar)
dc.date.accessioned2020-12-10T17:30:43Z
dc.date.accessioned2022-12-19T20:03:09Z
dc.date.available2020-12-10T17:30:43Z
dc.date.available2022-12-19T20:03:09Z
dc.date.created2020-12-10T17:30:43Z
dc.date.issued2020-04-15
dc.identifierBiochemical Engineering Journal. Amsterdam: Elsevier, v. 157, 12 p., 2020.
dc.identifier1369-703X
dc.identifierhttp://hdl.handle.net/11449/195324
dc.identifier10.1016/j.bej.2020.107529
dc.identifierWOS:000527325100007
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5375961
dc.description.abstractThe average shear rate (<(gamma)over dot>(av)) is a parameter used to characterize the shear environment in bioreactors, enabling comparison of the performances of different bioreactor models in terms of microorganism morphology and viability, and consequently bioproduct formation. Based on this approach, pneumatic bioreactors have been classified as low shear devices. However, the shear behavior cannot be generalized over a wide range of operating conditions, suggesting that the maximum shear rate (<(gamma)over dot>(max)) may be more suitable for the purpose of bioreactor performance comparison. Therefore, the aim of this work was to evaluate average and maximum shear rates in pneumatic bioreactors (bubble column and airlift), based on computational fluid dynamics (CFD) simulations. Concentric-duct and split airlift bioreactors exhibited higher <(gamma)over dot>(av) values, compared to the bubble column design, due to the nature of the liquid circulation patterns. The pneumatic bioreactors exhibited a significant (order of magnitude) difference between <(gamma)over dot>(av) (11.0-27.3 s(-1)) and <(gamma)over dot>(max) 4555 to 25,040 s(-1)), reflecting a non-uniform spatial distribution. The <(gamma)over dot>(max) values occurred close to the sparger holes and presented a linear relationship with gas injection velocity, which is dependent on the sparger geometry. In this way, sparger characteristics (number and diameter of sparger holes) defined <(gamma)over dot>(max) values in pneumatic bioreactors, showing that sparger should be properly designed in order to avoid excessive local shear rates.
dc.languageeng
dc.publisherElsevier B.V.
dc.relationBiochemical Engineering Journal
dc.sourceWeb of Science
dc.subjectPneumatic bioreactor
dc.subjectComputational fluid dynamics
dc.subjectShear rate
dc.subjectSparger design
dc.titleSparger design as key parameter to define shear conditions in pneumatic bioreactors
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución