dc.description.abstractAs estações de tratamento de esgoto sanitário que lançam efluentes tratados em corpos hídricos devem monitorá-los continuamente, a montante e a jusante dos emissários, de modo a evitar danos à saúde humana e ao ecossistema, além de atender às demandas do órgão ambiental. Todavia, durante o processo de licenciamento ambiental no Estado de Mato Grosso do Sul não são dadas orientações quanto à localização adequada dos pontos de monitoramento. Por meio do estudo de autodepuração dos corpos hídricos, que recebem efluentes sanitários tratados, os pontos de monitoramento de 49 (quarenta e nove) estações de tratamento de esgoto foram alocados, para locais que de fato são representativos da qualidade dos corpos receptores, considerando as zonas de degradação, zona de decomposição ativa, zona de recuperação e zona de áreas limpas. Para isto foi necessário estimar a vazão e caracterizar a qualidade dos corpos hídricos receptores e dos efluentes sanitários tratados nas 49 (quarenta e nove) estações de tratamento de esgoto bem como calcular/estimar os coeficientes necessários a modelagem.
dc.description.abstractThe wastewater treatment facilities that discharge effluents in water bodies should have continuous monitoring upstream and downstream from the pipe outfall, by the way to avoid damages for public health and ecossystems loss, beyond to follow demands of environmental state agency. However, during environmental permit process on Mato Grosso do Sul State the location of monitoring points are not oriented. Through of self-depuration studies for water bodies that receives treated effluent, the monitoring points for 49 (forty nine) wastewater treatment facilities have been defined for actually representative points by the water quality in water bodies, considering degradation zone, active decomposing zone, recovery zone and clean area zone. To achieve this were necessary to estimate flow rates and characterize the water bodies quality and treated effluent for 49 (forty nine) waste water treatment facilities as well calculate/estimate the needed coefficients for modeling.
dc.languagepor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rightsAcesso aberto
dc.subjectAutodepuração
dc.subjectModelagem
dc.subjectAmostragem
dc.subjectQualidade da água
dc.subjectSelf-depuration modeling
dc.subjectSampling
dc.subjectWater quality
dc.titleProposta de metodologia para locação de pontos de amostragem em corpos hídricos para monitoramento de estações de tratamento de esgoto sanitário