dc.contributorFernandes, Marco Antônio Rodrigues [UNESP]
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-01-24T16:31:02Z
dc.date.accessioned2022-12-19T19:19:00Z
dc.date.available2020-01-24T16:31:02Z
dc.date.available2022-12-19T19:19:00Z
dc.date.created2020-01-24T16:31:02Z
dc.date.issued2020-01-23
dc.identifierhttp://hdl.handle.net/11449/191432
dc.identifier000928561
dc.identifier33004064079P5
dc.identifier2307939425313065
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5372469
dc.description.abstractOs modernos sistemas de planejamentos de tratamento (Treatment Planning System - TPS) computadorizados possibilitam a análise de parâmetros que informam sobre a homogeneidade (Índice de Homogeneidade - IH) e a conformidade (Índice de Conformidade - IC) da distribuição de dose de radiação em todo o volume irradiado. O IH é determinado verificando o gradiente de dose de radiação em todo o volume de tratamento planejado (PTV), uma distribuição de dose perfeitamente homogênea implica em IH igual a zero. O IC representa o grau de conformidade entre a região do PTV coberta pela dose prescrita e o volume total do PTV, quanto mais próximo do valor 1,0 melhor a conformidade do tratamento. Nesta pesquisa foram analisados os índices IH e IC para 82 casos clínicos de pacientes anteriormente submetidos à radioterapia, comparando os valores calculados destes parâmetros em planejamentos realizados com a técnica radioterápica tridimensional conformacional (3D-CRT) com a técnica de radioterapia de intensidade modulada (IMRT), e correlacionando estes índices com a dose de radiação preconizada em cada um dos casos clínicos estudados. Os planejamentos radioterápicos foram efetuados em dois diferentes Sistemas de Planejamento de Tratamento (TPS), o TPS Eclipse e o TPS XiO. Os resultados apontam que os planejamentos feitos com a técnica de IMRT apresentam valores de IC e IH levemente melhores do que os obtidos com a técnica 3D-CRT.
dc.description.abstractModern Treatment Planning System (TPS) computerized allows the analysis of parameters that report on the homogeneity index (HI) and conformity index (CI) of radiation dose distribution throughout the irradiated volume. IH is determined by checking the radiation dose gradient across the PTV (planned treatment volume), a perfectly homogeneous dose distribution implies IH = zero. The IC represents the degree of conformity between the PTV region covered by the prescribed dose and the total PTV volume, the closer to 1.0 the better the treatment compliance. In this research IH and IC indices were analyzed for 82 clinical cases previously submitted to radiotherapy, comparing the calculated values of these parameters in three-dimensional conformal radiation therapy (3D-CRT) planning with the intensity modulated radiation therapy (IMRT) technique, and correlating these indices with radiation dose recommended in each of the clinical cases studied. Radiotherapy planning was carried out in two different treatment planning system (TPS): TPS Eclipse and TPS XiO. The results indicated that the plans made with the IMRT technique present slightly better IC and IH values than those obtained by 3DCRT technique.
dc.languagepor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rightsAcesso aberto
dc.subjectÍndice de conformidade
dc.subjectÍndice de homogeneidade
dc.subjectRadioterapia por intensidade modulada de feixe
dc.subjectRadioterapia tridimensional conformacional
dc.subjectConformity index
dc.subjectHomogeneity index
dc.subjectBeam intensity modulated radiotherapy
dc.subjectConformational three-dimensional radiotherapy
dc.titleAnálise do índice de conformidade e do índice de homogeneidade em planejamentos radioterápicos : comparação entre as técnicas de IMRT, 3D-CRT.
dc.typeTesis


Este ítem pertenece a la siguiente institución