dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade de São Paulo (USP)
dc.date.accessioned2019-10-06T15:25:51Z
dc.date.accessioned2022-12-19T18:27:05Z
dc.date.available2019-10-06T15:25:51Z
dc.date.available2022-12-19T18:27:05Z
dc.date.created2019-10-06T15:25:51Z
dc.date.issued2019-05-28
dc.identifierEuropean Journal of Sport Science, v. 19, n. 5, p. 645-652, 2019.
dc.identifier1536-7290
dc.identifier1746-1391
dc.identifierhttp://hdl.handle.net/11449/187111
dc.identifier10.1080/17461391.2018.1546338
dc.identifier2-s2.0-85057340701
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5368149
dc.description.abstractThe purpose of this study was to investigate the use of a single 3-min all-out maximal effort to estimate anaerobic capacity (AC) through the lactate and excess post-exercise oxygen consumption (EPOC) response methods (AC [La − ]+EPOCfast ) on a cycle ergometer. Eleven physically active men (age = 28.1 ± 4.0 yrs, height = 175.1 ± 4.2 cm, body mass = 74.8 ± 11.9 kg and ⩒O 2max = 40.7 ± 7.3 mL kg −1 min −1 ), participated in the study and performed: i) five submaximal efforts, ii) a supramaximal effort at 115% of intensity of ⩒O 2max, and iii) a 3-min all-out maximal effort. Anaerobic capacity was estimated using the supramaximal effort through conventional maximal accumulated oxygen deficit (MAOD) and also through the sum of oxygen equivalents from the glycolytic (fast component of excess post-exercise oxygen consumption) and phosphagen pathways (blood lactate accumulation) (AC [La − ]+EPOCfast ), while during the 3-min all-out maximal effort the anaerobic capacity was estimated using the AC [La − ]+EPOCfast procedure. There were no significant differences between the three methods (p > 0.05). Additionally, the anaerobic capacity estimated during the 3-min all-out effort was significantly correlated with the MAOD (r = 0.74; p = 0.009) and AC [La − ]+EPOCfast methods (r = 0.65; p = 0.029). Therefore, it is possible to conclude that the 3-min all-out effort is valid to estimate anaerobic capacity in physically active men during a single cycle ergometer effort.
dc.languageeng
dc.relationEuropean Journal of Sport Science
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectall-out efforts
dc.subjectAnaerobic capacity
dc.subjectcycle exercise
dc.subjectexcess post-exercise oxygen consumption
dc.subjectmaximal accumulated oxygen deficit
dc.title3-min all-out effort on cycle ergometer is valid to estimate the anaerobic capacity by measurement of blood lactate and excess post-exercise oxygen consumption
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución