Termografía acústica como apoyo complementario a la termografía infrarroja

dc.creatorReyna Regnoult, Rodney Ernesto
dc.creatorGonzález, Carlos Eduardo
dc.date2011-06-01
dc.date.accessioned2022-12-15T15:57:01Z
dc.date.available2022-12-15T15:57:01Z
dc.identifierhttps://revistas.unimilitar.edu.co/index.php/rcin/article/view/267
dc.identifier10.18359/rcin.267
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5355370
dc.descriptionA contrast in thermography is related to variations in temperature and emissions of surfaces analyzed. Typically, the interest focuses on temperature profiles, but they may be partly biased by the emissivity effect. Reflections on surface of system parts with radiation coming from other inner places as well as the effect of convective flows represent problems hindering a reading of thermal images in non-destructive tests. In this paper we developed a data acquisition system for 2D acoustic thermography to identify the effect of a convective flow reflection and complement the reading of images got by infrared thermography. So 40-kHz ultrasonic transducers were used to capture acoustic data, and we could obtain the temperature distribution in stationary conditions by hot air –gas– convection generated from heating components near surface.en-US
dc.descriptionEl contraste en la termografía, se relaciona con diferencias de temperatura y de emisividad de las superficies estudiadas. Por lo general, el interés está en determinar las temperaturas y poder compensar parcialmente el efecto de la emisividad. Las reflexiones en la superficie de partes del sistema de las radiaciones que provienen de otra parte del mismo, así como el efecto de flujos convectivos, representan inconvenientes que dificultan la interpretación de las imágenes termográficas de los Ensayos no Destructivos. En el presente trabajo, se desarrolló un sistema de adquisición de datos para generar imágenes de termografía acústica en el plano bidimensional, de manera que se pueda identificar los efectos de reflexión de flujos convectivos, como también complementar la interpretación de las imágenes obtenidas mediante la termografía infrarroja. Para capturar datos acústicos, se utilizaron transductores ultrasónicos de 40kHz y fue posible obtener la distribución de temperatura, en condiciones estacionarias de la convección del aire caliente (gas), que se generan de los elementos calefactores cerca de la superficie.es-ES
dc.formatapplication/pdf
dc.formattext/html
dc.languagespa
dc.publisherUniversidad Militar Nueva Granadaes-ES
dc.relationhttps://revistas.unimilitar.edu.co/index.php/rcin/article/view/267/77
dc.relationhttps://revistas.unimilitar.edu.co/index.php/rcin/article/view/267/1906
dc.relation/*ref*/Sadri A. (2005). "Non-destructive determination of and build-up thicknesses in operating furnaces using an acoustic ultrasonic reflection technique", Degradación de Materiales: Innovación, Inspección, Control y Rehabilitación, 44va Conferencia Anual de Metalurgistas del CIM, Calgary, Alberta, Canadá, pp. 371-385.
dc.relation/*ref*/Sandri A., Gebski P., Rojas Verazay P., Ibañez R., Díaz Chinga W. (2008). "Inspection and Evaluation of Refractory Lining for Slag Cleaning Furnace and Teniente Reactor at Fudación Hernán VIdela Lira Empresa Nacional de Minería (ENAMI)", 5ta Reunión Internacional sobre Mantenimiento de Plantas Mineras, Santiago, Chile, pp. 85-96.
dc.relation/*ref*/M. Ochs, T Horbach, A Schulz, R Koch and H-J Bauer (2009) "A novel calibration method for an infrared thermography system applied to heat transfer experiments" (Revista en linea) 075103, En: (http://iopscience.iop.org/0957-0233/20/7/075103)
dc.relation/*ref*/Ning Z., Yong J., Seizo K., (2005) "Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection" (Revista en linea), pp.509-522. En:(www.sciencedirect.com) [Consulta: 2009, junio 11]
dc.relation/*ref*/Iñiguez G (2007) "Clasificación mediante técnicas no destructivas y evaluación de las propiedades mecánicas de las maderas aserrada de coníferas de gran escuadría para uso estructural". (Resumen en linea) Tesis doctoral no publicada, Facultad de Física, Universidad Politécnica de Madrid. En: (http://oa.upm.es/415/) [Consulta: 2009, junio 14]
dc.relation/*ref*/Soto, J., (1996). Fundamento sobre Ahorro de Energía. Yucatán., México: FOMES.
dc.rightsDerechos de autor 2016 Ciencia e Ingeniería Neogranadinaes-ES
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0es-ES
dc.sourceCiencia e Ingenieria Neogranadina; Vol. 21 No. 1 (2011); 5-16en-US
dc.sourceCiencia e Ingeniería Neogranadina; Vol. 21 Núm. 1 (2011); 5-16es-ES
dc.sourceCiencia e Ingeniería Neogranadina; v. 21 n. 1 (2011); 5-16pt-BR
dc.source1909-7735
dc.source0124-8170
dc.subjectAcoustic thermographyen-US
dc.subjectinfrared thermographyen-US
dc.subjectgas flow.en-US
dc.subjecttermografía acústicaes-ES
dc.subjecttermografía infrarojaes-ES
dc.subjectflujo de gases-ES
dc.titleAn acoustic thermography as an additional support to infrared thermographyen-US
dc.titleTermografía acústica como apoyo complementario a la termografía infrarrojaes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución