Effector ans sensor selection to ankle and knee of EMI-UMNG.
Selección de actuadores y sensores para el tobillo y la rodilla de EMI-UMNG
dc.creator | Oliveros Acosta, Eduardo | |
dc.creator | Quintero, Virgilio | |
dc.creator | Velasco Toledo, Nelson | |
dc.date | 2013-06-01 | |
dc.date.accessioned | 2022-12-15T15:55:08Z | |
dc.date.available | 2022-12-15T15:55:08Z | |
dc.identifier | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/232 | |
dc.identifier | 10.18359/rcin.232 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/5355336 | |
dc.description | Heavy objects are typically transported by wheeled vehicles, but many environments such as rocky slopes, stairs, etc., cause significant challenges to this type of locomotion. The lower limb exoskeleton for the Universidad Militar Nueva Granada (EMIUMNG) is a robotic system that provides to the operator the ability to withstand substantial loads with minimal effort on any terrain. The performance of an exoskeleton and control are problems of interest because of the precision to follow the movements of a user, avoiding injure or hinder task performance. This paper presents the design and simulation of the performance of the exoskeleton system additionally presents the selection criterion for sensors for each of the joints. Kinematic parameters are shown as the maximum speed of the actuators in the exoskeleton system EMI (Exoskeleton for Lower Limbs) of Universidad Militar Nueva Granada. | en-US |
dc.description | Los objetos pesados son transportados típicamente por vehículos de ruedas; sin embargo, muchos ambientes como laderas rocosas, escaleras, etc, plantean importantes desafíos para este tipo de sistema de locomoción. El Exoesqueleto para miembros inferiores de la Universidad Militar Nueva Granada (EMI-UMNG) es un sistema robótico que proporciona a su operador la capacidad para soportar cargas considerables con un esfuerzo mínimo sobre cualquier tipo de terreno. La actuación y control de un exoesqueleto presenta un problema de interés debido a la precisión para seguir lo movimientos de un usuario, evitando lesionarlo u obstaculizar la realización de tareas. Este artículo presenta el diseño y simulación del sistema de actuación del exoesqueleto, adicionalmente se presentan los criterios de selección para los sensores para cada una de las articulaciones. Se muestran parámetros cinemáticos como la máxima velocidad de desplazamiento de los actuadores en el sistema exoesquelético EMI (Exoesqueleto para Miembros Inferiores) de la Universidad Militar Nueva Granada. | es-ES |
dc.format | application/pdf | |
dc.format | text/html | |
dc.language | spa | |
dc.publisher | Universidad Militar Nueva Granada | es-ES |
dc.relation | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/232/42 | |
dc.relation | https://revistas.unimilitar.edu.co/index.php/rcin/article/view/232/1869 | |
dc.relation | /*ref*/Zoss, A.;Kazerooni, H.; Chu, A. (2005) On the mechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX); International Conference on Intelligent Robots and Systems, pp 3465 – 3472. http://dx.doi.org/10.1109/iros.2005.1545453 | |
dc.relation | /*ref*/Makinson, B. (1971)Research and development prototype for machine augmentation of human strength and endurance. New York. National Technical Information Service. | |
dc.relation | /*ref*/Vukobratovic, M.;Hristic, D.;Stojiljkovic, Z. (1974) Development of active anthropomorphic exoskeletons; Medical and Biological Engineering and Computing, Vol. 12, pp 66 – 80. http://dx.doi.org/10.1007/BF02629836 | |
dc.relation | /*ref*/Kazerooni, H.;Guo, J. (1993) Human extenders;Journal of Dynamic Systems, Measurement and Control, Vol. 115, pp 281 – 290. http://dx.doi.org/10.1115/1.2899068 | |
dc.relation | /*ref*/Yoshimitsu, T.; Yamamoto, K. (2004) Development of a power assist suit for nursing work; SICE 2004 Annual Conference, Vol. 1, pp 577 – 580. | |
dc.relation | /*ref*/Restrepo M.; Estrada J.;Camacho J.; Parámetros antropométricos de la población laboral colombiana 1995. Universidad de Antioquia Instituto de Seguros Sociales, 1995. | |
dc.relation | /*ref*/Instituto Tecnológico y de Estudios Superiores de Monterrey Campus Morelos. Antropometría. Laboratorio de Producción, 2008. | |
dc.relation | /*ref*/Morales Heredia, J. A. y Palacios Salamanca B. D.; Dise-o mecánico y sistema de sujeción de un exoesqueleto para miembros inferiores; Bogotá, 2010, 85p. Trabajo de Grado (Ingeniero en Mecatrónica). Universidad Militar Nueva Granada; Facultad de Ingeniería. | |
dc.relation | /*ref*/Gama Nathalia; Análisis cinemático y dinámico de la marcha normal humana. Bogotá, 2010, 35p, Trabajo de Grado (Ingeniero en Mecatrónica). Universidad Militar Nueva Granada; Facultad de Ingeniería. | |
dc.relation | /*ref*/Iba-ez Edwin; Sistema para la estimación de fuerza en los movimientos de flexión y extensión de rodilla; Bogotá, 2012, 74p, Trabajo de Grado (Ingeniero en Mecatrónica). Universidad Militar Nueva Granada; Facultad de Ingeniería. | |
dc.relation | /*ref*/Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, Guendelman E, Thelen DG. (2007)OpenSim: Open-source Software toCreate and Analyze Dynamic Simulations of Movement. IEEE Transactions on Biomedical Engineering. http://dx.doi.org/10.1109/TBME.2007.901024 | |
dc.relation | /*ref*/FESTO. Válvula proporcional de vías MPYE, manual On-line. Disponible en: http://www.festo.com/cat/es-co_co/products_MPYE_1. Consultado en Febrero 2013. | |
dc.relation | /*ref*/FESTO. Cilindro normalizado DSBC, manual On-line. Disponible en: http://www.festo.com/cat/es-co_co/products_DSBC. Consultado en Marzo 2013. | |
dc.relation | /*ref*/FESTO. Sistema de medición de recorrido MLO-POT-LWG, manual On-line. Disponible en: http://www.festo.com/cat/es-co_co/products_WMS_MLO_LWG_1. Consultado en: Marzo 2013. | |
dc.rights | Derechos de autor 2016 Ciencia e Ingeniería Neogranadina | es-ES |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0 | es-ES |
dc.source | Ciencia e Ingenieria Neogranadina; Vol. 23 No. 1 (2013); 61-75 | en-US |
dc.source | Ciencia e Ingeniería Neogranadina; Vol. 23 Núm. 1 (2013); 61-75 | es-ES |
dc.source | Ciencia e Ingeniería Neogranadina; v. 23 n. 1 (2013); 61-75 | pt-BR |
dc.source | 1909-7735 | |
dc.source | 0124-8170 | |
dc.title | Effector ans sensor selection to ankle and knee of EMI-UMNG. | en-US |
dc.title | Selección de actuadores y sensores para el tobillo y la rodilla de EMI-UMNG | es-ES |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:eu-repo/semantics/publishedVersion |