dc.description.abstractEste trabalho analisou o desempenho energético da envoltória de um prédio residencial multifamiliar de alto padrão em Florianópolis. Todos os ambientes de permanência prolongada das 12 unidades habitacionais da edificação foram estudados. Para isso foi utilizado o método simplificado da Instrução Normativa Inmetro para Classe de Eficiência Energética de Edificações Residenciais. Por meio do metamodelo oferecido pelo método foram calculadas as cargas térmicas das áreas de permanência prolongada, sendo utilizados como dados de entrada características das unidades habitacionais, como suas dimensões, orientações e propriedades térmicas dos materiais utilizados. As cargas térmicas da edificação na condição base foram comparadas com a da edificação na condição de referência, que tem características pré definidas pelo método. Com os resultados do metamodelo foi analisado quais apartamentos precisariam de alterações para que alcançassem o nível máximo de eficiência energética. Observando as cargas térmicas de cada APP foi possível decidir mais precisamente quais delas precisariam de alterações e que alterações seriam mais impactantes. As propostas de medidas de eficiência energética se resumiam em alterar a envoltória da edificação de maneira mais simples possível, fazendo com que a mesma chegasse ao nível máximo de eficiência energética. Em alguns casos a redução da carga térmica, em comparação com a condição de referência, passou de valores próximos a 70% para valores próximos a 90%. Alcançado o nível máximo para todos os apartamentos, foi feita uma análise de viabilidade para a aplicação das medidas de eficiência energética por meio do payback corrigido e da taxa interna de retorno. Para todos apartamentos os investimentos tiveram retorno em pelo menos cinco anos e apresentaram uma taxa interna de retorno entre 6% e 30%. Todas as alterações propostas, utilização de cores claras na cobertura e emprego de venezianas nas janelas, se mostraram viáveis economicamente.
dc.description.abstractThis papear analyzed the energetic performance of the envelope of a high-standard multyfamily residential building in Florianópolis. All the environments of prolonged stay of the twelve housing units of the building were studied. For this, the simplified method of the Normative Instruction Inmetro for Class of Energy Efficiency of Residential Buildings was used. Through the metamodel provided by the method were calculated the termal loads of the areas of prolonged stay, being used as input data chatacteristics of housing units, as their dimensions, bearings and termal properties of the materials used. The termal loads of the building in the base condition were compared with the termal loads of the building in the reference condition, wich has characteristics pre-defined by the method. With the results of the metamodel it was analyzed wich apartments would need changes in order to reach the maximum level of energy efficiency. By observing the termal loads of each area of prolonged stay it was possible to decide more precisely which ones would need to be altered and which changes would be more impacting. These proposal were made to change the envelope of the building in the simplest way possible, making it reach the maximum level of energy efficiency. In some cases the reduction of the termal load, compared to the reference condition, went from values close to 70% to values close to 90%. Once the maximum level was reached, a financial feasibility analysis was performed for the application of energy efficiency measures through corrected payback and internal rate of return. For all apartments, the investments returned for at least five years and showed an internal rate of return between 6% and 30%. All proposed changes, the use of light colors on the roof and the use of window blinds, were economically viable.
dc.languagept_BR
dc.publisherFlorianópolis, SC
dc.subjectEficiência Energética em Edificações
dc.subjectBuilding Energy Efficiency
dc.subjectInstrução Normativa Inmetro para Classe de Eficiência Energética de Edificações Residenciais
dc.subjectNormative Instruction Inmetro for Energy Efficiency Class of Residential Buildings
dc.subjectMedidas de Eficiência Energética
dc.subjectEnergy Efficiency Measures
dc.titleAvaliação da eficiência energética de uma edificação multifamiliar por meio da INI-R