dc.identifierLANGE, Sérgio Costa. Avaliação de um sistema de resfriamento passivo para o clima de Curitiba. 2016. 85 f. Dissertação (Mestrado em Tecnologia) - Universidade Tecnológica Federal do Paraná, Curitiba, 2016.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/1800
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5270468
dc.description.abstractDirect evaporative cooling systems (DECS) based on sprinkling water indoors in the form of droplets and indirect evaporative cooling systems (IECS), characterized by the use of wetted roof or wall surfaces for cooling without increasing the indoor air moisture, consist of interesting bioclimatic strategies still not quite explored in Brazil. This study aims to evaluate the use of a particular form of IECS (which combines evaporative cooling and thermal mass brought about by a water reservoir) for indoor thermal control in warm conditions in Curitiba, Two test cells were initially built, monitored and compared to each other: a control module (CM) and an experimental module (EM), the latter provided with an evaporative pond. A subsequent configuration of the system which cancels out the evaporative function of the system and that is solely based on the increase of thermal mass, was tested in a second monitoring round. A third configuration of EM combinig evaporative cooling and the increase of termal mass was tested. Results showed a higher effectiveness of the IECS for the indoor cooling of the tested cells. The average temperature in EM was reduced in 2.5°C and the maximum temperature was reduced in 8.0°C in comparison with the CM. Results also showed a strong relation between the wet-bulb temperature depression and the internal temperature decrease achieved by the evaporative cooling strategy.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Tecnologia
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectResfriamento evaporativo - Curitiba (Paraná)
dc.subjectTemperatura atmosférica
dc.subjectRefrigeração
dc.subjectTecnologia
dc.subjectEngenharia civil
dc.subjectEvaporative cooling - Curitiba (Paraná)
dc.subjectAtmospheric temperature
dc.subjectRefrigeration and refrigerating machinery
dc.subjectTechnology
dc.subjectCivil engineering
dc.titleAvaliação de um sistema de resfriamento passivo para o clima de Curitiba
dc.typemasterThesis