dc.contributorConceição, André Luiz Coelho
dc.contributorhttp://lattes.cnpq.br/4210821988600111
dc.contributorAntoniassi, Marcelo
dc.contributorhttp://lattes.cnpq.br/0578844762031850
dc.contributorConceição, André Luiz Coelho
dc.contributorRibeiro Júnior, Sebastião
dc.contributorGodoi, Walmor Cardoso
dc.contributorFilipov, Danielle
dc.creatorBadelli, Juliana do Carmo
dc.date.accessioned2017-12-28T03:24:04Z
dc.date.accessioned2022-12-06T15:39:04Z
dc.date.available2017-12-28T03:24:04Z
dc.date.available2022-12-06T15:39:04Z
dc.date.created2017-12-28T03:24:04Z
dc.date.issued2017-03-15
dc.identifierBADELLI, Juliana do Carmo. Desenvolvimento de phantom de mama para estudo de imagens por contraste de fase. 2017. 83 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) - Universidade Tecnológica Federal do Paraná, Curitiba, 2017.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/2864
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5268768
dc.description.abstractBecause of the large number of cases of breast cancer and its increasing incidence rate, new techniques of imaging are being studied. With the aim to provide better conditions for visualization and detection of this disease, in complement of the information obtained by mammography, the techniques of phase contrast imaging have been studied. Thus, the objective of the present study was to develop a breast phantom for application in phase contrast images. This phantom is a cylinder with some inserts filled with equivalent materials to normal and pathological breast tissues, such as: polymethylmethacrylate (PMMA), ethanol, dimethylformamide and glycerol. These materials were chosen due to the similarity in the attenuation and scattering properties of breast tissues. Among the techniques to demonstrate phase contrast, it was used the propagation technique. The experimental arrangement was elaborated taking into account the calculations to obtain the phase contrast using the instrumentation for X-ray microtomography of the Lactec Institute. Radiographic and microtomographic images were acquired by transmission and by phase contrast and then compared. The comparison between the analyzed images showed significant improvements in the contrast, mainly in the edges of the cylinders present in the phantom. Therefore, the phantom developed in this work can be used to optimize the acquisition and treatment parameters of phase contrast images for application in the detection of breast cancer.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Elétrica e Informática Industrial
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectImagens e fantasmas (Radiologia)
dc.subjectMamas - Doenças - Diagnóstico
dc.subjectMamas - Câncer
dc.subjectMétodos de simulação
dc.subjectEngenharia biomédica
dc.subjectEngenharia elétrica
dc.subjectPhantoms (Radiology)
dc.subjectBreast – Diseases - Diagnosis
dc.subjectBreast - Cancer
dc.subjectSimulation methods
dc.subjectBiomedical engineering
dc.subjectElectric engineering
dc.titleDesenvolvimento de phantom de mama para estudo de imagens por contraste de fase
dc.typemasterThesis


Este ítem pertenece a la siguiente institución