dc.contributorPaschuk, Sergei Anatolyevich
dc.contributorhttps://orcid.org/0000-0001-5125-0163
dc.contributorhttp://lattes.cnpq.br/5290164798310287
dc.contributorSchelin, Hugo Reuters
dc.contributorhttps://orcid.org/ 0000-0002-2074-4408
dc.contributorhttp://lattes.cnpq.br/1506878029093299
dc.contributorSchelin, Hugo Reuters
dc.contributorhttps://orcid.org/ 0000-0002-2074-4408
dc.contributorhttp://lattes.cnpq.br/1506878029093299
dc.contributorSetti, Joao Antonio Palma
dc.contributorhttps://orcid.org/0000-0003-0659-1297
dc.contributorhttp://lattes.cnpq.br/5231547788496074
dc.contributorAssis, Joaquim Teixeira de
dc.contributorhttps://orcid.org/0000-0002-4027-6939
dc.contributorhttp://lattes.cnpq.br/7307238902576135
dc.contributorHormaza, Joel Mesa
dc.contributorhttps://orcid.org/ 0000-0001-6519-5118
dc.contributorhttp://lattes.cnpq.br/8949540199759267
dc.contributorPaschuk, Sergei Anatolyevich
dc.contributorhttps://orcid.org/0000-0001-5125-0163
dc.contributorhttp://lattes.cnpq.br/5290164798310287
dc.creatorLourenco, Jose Carlos de Camargo
dc.date.accessioned2021-09-13T21:09:40Z
dc.date.accessioned2022-12-06T15:22:29Z
dc.date.available2021-09-13T21:09:40Z
dc.date.available2022-12-06T15:22:29Z
dc.date.created2021-09-13T21:09:40Z
dc.date.issued2021-05-12
dc.identifierLOURENÇO, José Carlos de Camargo. Modelo para estimar doses acumuladas em tempo real para procedimentos intervencionistas. 2021. Tese (Doutorado em Engenharia Elétrica e Informática Industrial) - Universidade Tecnológica Federal do Paraná, Curitiba, 2021.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/25997
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5264876
dc.description.abstractIn interventionist procedures that use fluoroscopy, medical staff is exposed to ionizing radiation, often with doses exceeding the recommended limits. These doses are only observed at the end of the procedure, or after one month utilizing individual dosimeters. The objective of the present study was to develop a method to estimate doses of ionizing radiation in realtime during the interventionist medical procedure using fluoroscopy. The performance of the remote-controlled fluoroscopy system in scattered radiation measurements was tested at 50 kV and 30 mA with a Ludlum 9DP ionization chamber and a PMMA phantom. Dose rates were collected by the ionization chamber for the gonad regions at 90 cm, for the hands at 109, for the chest at 128 and the lens of the eyes at 166 cm with the ground level about the beam distances main at 19, 38, 76 and 152 cm, around the 45 to 45-degree fluoroscopy table. To estimate doses in real-time, an ionization chamber was attached to the top of the fluoroscopy table and used as a fixed reference point. The collected data were sent to the developed software to determine the estimated doses. The numerical values of the estimated doses are visualized in real-time using a monitor showing the intensities of the accumulated doses, with a visual indication of the color scale of the doses received by the members of the medical team in the position they are concerning the table To validate the estimate doses in a real-time system, the hypothesis of the measured dose rates and the estimated real-time measures were implemented using Student’s t-test for independent samples with a significance level of 5%. We evaluated the estimate of the equivalent dose in a scattered object during an average time of exposure to scattered radiation in 20 minutes, which corresponds on average to an interventionist procedure, and we find, respectively, the following estimates in the scattered dimension object 30x30x15 cm: for the gonad region at 539, 159, 76, 42, and 22 μSv; for hands at 858, 392, 172, 74 and 22 μSv; for the chest at 539, 282, 152, 98 and 22 μSv; and the lens of the eyes 221, 159, 110, 78 and 22 μSv, which correspond to the X-ray beam distances in 19, 38, 57, 76 and 152 cm respectively around the fluoroscopy table. The results are similar according to the literature. The estimated dose in real-time helps the interventionist physician optimize their exposure to scattered radiation during the intervention procedure, allowing them to enhance personal protection and reduce the occupational dose.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Elétrica e Informática Industrial
dc.publisherUTFPR
dc.rightshttp://creativecommons.org/licenses/by/4.0/
dc.rightsopenAccess
dc.subjectEstimativa de parâmetros
dc.subjectFluoroscopia
dc.subjectRadiação - Dosimetria
dc.subjectRadiação - Efeito fisiológico
dc.subjectSoftware - Desenvolvimento
dc.subjectMétodos de Simulação
dc.subjectParameter estimation
dc.subjectFluoroscopy
dc.subjectRadiation dosimetry
dc.subjectRadiation - Physiological effect
dc.subjectComputer software - Development
dc.subjectSimulation methods
dc.titleModelo para estimar doses acumuladas em tempo real para procedimentos intervencionistas
dc.typedoctoralThesis