dc.creatorTurqueti, Carlos Augusto D'Orazio
dc.date.accessioned2018-03-09T20:56:18Z
dc.date.accessioned2022-12-06T15:21:09Z
dc.date.available2018-03-09T20:56:18Z
dc.date.available2022-12-06T15:21:09Z
dc.date.created2018-03-09T20:56:18Z
dc.date.issued2017-08-31
dc.identifierTURQUETI, Carlos Augusto D'Orazio. Desenvolvimento de um goniômetro indutivo com bobinas ortogonais para aplicações biomédicas. 2017. 81 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Tecnológica Federal do Paraná, Curitiba, 2017.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/2983
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5264550
dc.description.abstractThis dissertation describes the development of an inductive goniometer for the measurement of joint angle. The goniometer aims to measure angles up to 360 ° and the possibility of measurement in joints with more than one degree of freedom. For this it uses as base the work of Laskoski (2010) and aeronautical navigation systems. The experiment performed by Laskoski (2010) makes measurements up to 180 ° and the coils need to be aligned. The systems used in aeronautical navigations use the electronic compass and the automatic direction finder, that systems work with magnitudes in the order of kilometers. This experiment aims to adapt the navigation systems using the magnetic field to be able to measure angles at small distances. The tests were satisfactory comparing the errors found with the results of the experiments of Laskoski (2010) and Carbonaro et al. (2014). The maximum error over a distance of 7.5 cm is 10.6 ° and the misalignment between the coils of + 20 ° and -20 ° generates an error of at most 1.71 °.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Biomédica
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectArticulações - Amplitude de movimento - Medição
dc.subjectArticulações - Hipermobilidade - Medição
dc.subjectEngenharia biomédica
dc.subjectIndução eletromagnética
dc.subjectJoints - Range of motion - Measurement
dc.subjectJoints - Hypermobility - Measurement
dc.subjectBiomedical engineering
dc.subjectElectromagnetic induction
dc.titleDesenvolvimento de um goniômetro indutivo com bobinas ortogonais para aplicações biomédicas
dc.typemasterThesis