dc.contributorSchelin, Hugo Reuters
dc.creatorPorto, Lorena Elaine
dc.date.accessioned2015-02-27T14:23:33Z
dc.date.accessioned2022-12-06T15:09:14Z
dc.date.available2015-02-27T14:23:33Z
dc.date.available2022-12-06T15:09:14Z
dc.date.created2015-02-27T14:23:33Z
dc.date.issued2014-12-11
dc.identifierPORTO, Lorena Elaine. Avaliação da dose em pacientes pediátricos submetidos a exame de tomografia computadorizada. 2014. 115 f. Tese (Doutorado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2014.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/1070
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5261580
dc.description.abstractThe computed tomography (CT) dosimetry involves measurements of specific quantities of CT, which are part of CT quality control procedures, as well as calculation of absorbed and effective doses to a patient submitted to CT examinations. Since CT uses ionizing radiation, it should be considered that a precise balance between risks and benefits must be achieved in order to justify the adoption of such technique. Radiation protection of patients undergoing radiological exams is established based on the justification and optimization principles. Nowadays, it is important to know the dose radiation levels to which a patient is exposed during a tomographic procedure. Those are given by the estimation of specific dosimetric quantities called the computed tomography kerma index in air, C100,air, the weighted computed tomography kerma index Cw, kerma length product, PKL,CT and then the levels of effective dose and risk to the computerized CT scan study of skull, thorax and abdomen with a multiple scanning. The values obtained were compared with those obtained by computer simulation using Monte Carlo method. The protection quantities organ absorbed dose, effective dose and risk for comparison with the reference dose level established by the European Community. Using computational simulation program of the Dosecal X_CT and the ICRP 103 Protocol, were certain quantities of radiation protection relevant to study which are the values of effective dose for the procedure. The dose length product PKL,CT level was calculated from the C100,air and compared to the reference dose level established by the European Community. The values found so far are within the limits of the reference levels.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherPrograma de Pós-Graduação em Engenharia Elétrica e Informática Industrial
dc.subjectRadiação - Dosimetria
dc.subjectTomografia
dc.subjectPediatria
dc.subjectRadiação ionizante - Medidas de segurança
dc.subjectRadiografia - Qualidade da imagem
dc.subjectMonte Carlo, Método de
dc.subjectSimulação (Computadores)
dc.subjectEngenharia biomédica
dc.subjectEngenharia elétrica
dc.subjectRadiation dosimetry
dc.subjectTomography
dc.subjectPediatrics
dc.subjectIonizing radiation - Safety measures
dc.subjectRadiography - Image quality
dc.subjectMonte Carlo method
dc.subjectComputer simulation
dc.subjectBiomedical engineering
dc.subjectElectric engineering
dc.titleAvaliação da dose em pacientes pediátricos submetidos a exame de tomografia computadorizada
dc.typedoctoralThesis


Este ítem pertenece a la siguiente institución