dc.description.abstractThis paper’s purpose was to prove the benefits of sealing structures on constructions through a study about water absorption and the capillary absorbency on foundations. For this experiment was built prototypes of the foundation and the first brick row, where some of them remained without sealing, some of them was sealed only on the foundation and some of them was sealed on the foundation and on the mortar of the first brick row. The difference of weight of the prototypes with and without sealing wasn’t subtle. This information proved the initial theory of the foundation’s property of absorption by capillarity and confirmed the relevance of a good sealing on ´building construction.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCampo Mourao
dc.publisherBrasil
dc.publisherDepartamento Acadêmico de Construção Civil
dc.publisherEngenharia Civil
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectImpermeabilização
dc.subjectVigas
dc.subjectInfiltração
dc.subjectWaterproofing
dc.subjectGirders
dc.subjectSeepage
dc.titleAnálise de protótipo de vigas baldrame submetido a ação agressiva da água
dc.typebachelorThesis


Este ítem pertenece a la siguiente institución