dc.identifier | MORAES, Fábio Brignol de. Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos. 2013. 135 f. Dissertação (Mestrado em Engenharia Elétrica e Informática Industrial) – Universidade Tecnológica Federal do Paraná, Curitiba, 2013. | |
dc.identifier | http://repositorio.utfpr.edu.br/jspui/handle/1/797 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/5257479 | |
dc.description.abstract | This work presents a study on electromagnetic interference radiated and conducted emissions generated by the lighting system and the electrosurgery unit (eletric scalpel) in na operating room of a hospital in Pato Branco / PR. The work consisted of measurements of conducted and radiated emission of fluorescent lighting systems in the laboratory of conducted and radiated “in loco” electrosurgery unit emissions. Futhermore, a study was made of references on standarts, national and international, that focus on these two systems. Because of the work, has an overview on the situation of conducted and radiated emissions, the fluorecent lighting used in electrosurgical unit and hospital systems. | |
dc.publisher | Universidade Tecnológica Federal do Paraná | |
dc.publisher | Curitiba | |
dc.publisher | Programa de Pós-Graduação em Engenharia Elétrica e Informática Industrial | |
dc.subject | Interferência eletromagnética | |
dc.subject | Medição | |
dc.subject | Instrumentos e aparelhos médicos | |
dc.subject | Lâmpadas fluorescentes - Iluminação | |
dc.subject | Normas técnicas (Engenharia) | |
dc.subject | Engenharia biomédica | |
dc.subject | Engenharia elétrica | |
dc.subject | Electromagnetic interference | |
dc.subject | Mensuration | |
dc.subject | Medical instruments and apparatus | |
dc.subject | Fluorescent lamps - Lighting | |
dc.subject | Standards, Engineering | |
dc.subject | Biomedical engineering | |
dc.subject | Electric engineering | |
dc.title | Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos | |
dc.type | masterThesis | |