dc.contributorSchneider Junior, Bertoldo
dc.contributorhttps://orcid.org/0000-0002-7240-9652
dc.contributorhttp://lattes.cnpq.br/3675060302477169
dc.contributorJakubiak, Rosangela Requi
dc.contributorhttps://orcid.org/0000-0003-4258-6612
dc.contributorhttp://lattes.cnpq.br/9416396245605040
dc.contributorMiquelin, Charlie Antoni
dc.contributorhttps://orcid.org/0000-0003-2922-596X
dc.contributorhttp://lattes.cnpq.br/2797875007644990
dc.contributorSchelin, Hugo Reuters
dc.contributorhttps://orcid.org/0000-0002-2074-4408
dc.contributorhttp://lattes.cnpq.br/1506878029093299
dc.contributorJakubiak, Rosangela Requi
dc.contributorhttps://orcid.org/0000-0003-4258-6612
dc.contributorhttp://lattes.cnpq.br/9416396245605040
dc.creatorGriebler, Cristian Felipe
dc.date.accessioned2021-04-08T18:16:03Z
dc.date.accessioned2022-12-06T14:38:31Z
dc.date.available2021-04-08T18:16:03Z
dc.date.available2022-12-06T14:38:31Z
dc.date.created2021-04-08T18:16:03Z
dc.date.issued2020-10-22
dc.identifierGRIEBLER, Cristian Felipe. Avaliação da diferença de potencial elétrico do tubo de raios X em equipamentos de radiologia convencional e mamografia. 2020. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Tecnológica Federal do Paraná, Curitiba, 2020.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/24698
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5253127
dc.description.abstractThe evaluation of the potential difference of X-ray equipment is a fundamental item in the quality control program of a radiodiagnosis clinic. This evaluation is important to ensure the patient’s radiological protection and to guarantee the quality of the exam image. The image quality is responsible for the correct diagnosis of the exam. National standards, Portaria 453/98 and the recent RDC 330/19, establish different operating limits for the voltage produced by the equipment’s X-ray tube and do not present a clear definition for the term voltage. The objective of this work was to evaluate the performance of three X-ray equipments and three mammographic equipments through the tests of accuracy and reproducibility established in the national standard. Mean peak voltage, practical peak voltage and maximum peak voltage were measured by the Accu-Gold AGMS-D and AGMS-M sensors, and the values provided by the Accu-Gold Radcal software. The voltage values evaluated for the six devices were within the tolerance limits established in the standard for the accuracy and reproducibility tests. Accuracy tests, among conventional X-ray equipment, showed deviations from 0.16 to 6.25% compared to the nominal voltage. Among mammography equipments, the deviations were from 0.33 to 3.2% to the nominal voltage. Reproducibility tests, among conventional X-ray equipment, showed deviations of 0.11 to 0.82% compared to the nominal voltage. Among mammography equipments, the deviations were 0.3 to 0.5 kV and the coefficient of variation (CV) was less than 0.02. In this work, the importance of quality control tests and the need for multiprofessional colaboration were verified. It is concluded that, in parallel to the quality control tests, multiprofessional performance is an essential practice to guarantee the quality of the radiodiagnostic exam.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Biomédica
dc.publisherUTFPR
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsopenAccess
dc.subjectRaios X - Diagnóstico
dc.subjectControle de qualidade - Testes
dc.subjectFísica médica
dc.subjectDiagnóstico radioscópico
dc.subjectRaios X - Equipamento e acessórios
dc.subjectRaios X - Medidas de segurança
dc.subjectX-rays - Diagnosis
dc.subjectQuality control - Testing
dc.subjectMedical physics
dc.subjectDiagnosis, Radioscopic
dc.subjectX-rays - Equipment and supplies
dc.subjectX rays - Safety measures
dc.titleAvaliação da diferença de potencial elétrico do tubo de raios X em equipamentos de radiologia convencional e mamografia