dc.identifierDUMAS JUNIOR, Adair. Estudo metrológico volumétrico de bombas de infusão peristálticas lineares. 2016. 77 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Tecnológica Federal do Paraná, Curitiba, 2016.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/2039
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5252668
dc.description.abstractThis study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Biomédica
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectBombas de infusão de drogas - Calibração
dc.subjectMedição
dc.subjectTeoria dos erros
dc.subjectInstrumentos e aparelhos médicos - Testes
dc.subjectEngenharia biomédica
dc.subjectDrug infusion pumps - Calibration
dc.subjectMensuration
dc.subjectError analysis (Mathematics)
dc.subjectMedical instruments and apparatus - Testing
dc.subjectBiomedical engineering
dc.titleEstudo metrológico volumétrico de bombas de infusão peristálticas lineares
dc.typemasterThesis