dc.contributorDenyak, Valeriy
dc.contributorhttp://lattes.cnpq.br/9723527574588682
dc.contributorSetti, João Antônio Palma
dc.contributorhttp://lattes.cnpq.br/5231547788496074
dc.contributorFilipov, Danielle
dc.contributorhttp://lattes.cnpq.br/8016402520749990
dc.contributorSchelin, Hugo Reuters
dc.contributorhttp://lattes.cnpq.br/1506878029093299
dc.contributorDenyak, Valeriy
dc.contributorhttp://lattes.cnpq.br/9723527574588682
dc.creatorNunes, Gracielly Soares
dc.date.accessioned2020-05-14T21:55:39Z
dc.date.accessioned2022-12-06T14:30:31Z
dc.date.available2020-05-14T21:55:39Z
dc.date.available2022-12-06T14:30:31Z
dc.date.created2020-05-14T21:55:39Z
dc.date.issued2020-03-13
dc.identifierNUNES, Gracielly Soares. Avaliação de dose ocupacional e parâmetros técnicos em seriografias de esôfago, estômago e duodeno pediátricas. 2020. Dissertação (Mestrado em Engenharia Biomédica) - Universidade Tecnológica Federal do Paraná, Curitiba, 2020.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/4947
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5250498
dc.description.abstractStudies of pediatric upper gastrointestinal series performed by fluoroscopy usually require professionals to remain within the examination room to positioning and immobilizing the patient. Knowing and reducing radiation exposure of these individuals is a constantly reported concern. Thus, the present study aimed to estimate the effective dose received by the team involved in pediatric Esophagus, Stomach e Duodenum Seriography. Dose rates and cumulative doses were measured using a parallel plate ionization chamber (Radcal Corporation, model 10X5-6, with a sensitive volume of 180 cm³), for each of the five examination steps. To simulate the occupationally exposed individual and the pediatric patient, two polyethylene dummies filled with water were used. Were also evaluated some technical parameters that influence dose distributions, such as collimation, isocenter distance, lead apron and additional filtration. The results were compared with the literature and with limits set by international standards. The estimate showed values slightly lower, but comparable, to typical medical doses of chest X-rays. The annual effective dose is capable of exceeding the International Commission on Radiological Protection threshold if expanded to hundreds of procedures. For different exam positions, the difference in dose rate is up to 14% and doses in radiography differ by a factor of up to 3.4. The contribution of radiographic images in the total dose may reach 30%, which emphasizes the importance of the last image hold for occupational exposure. The automatic brightness control increases the dose rate to compensate for collimator close. Regarding the variable distance, the dose rate follows the inverse square law, with an accuracy of better than 1%. For tube voltage of 83 kVp, the lead apron decreases the scattered radiation dose rate similar to 49 keV monochrome radiation. The additional filtration suggested by the European Communities reduces the dose rate by tens of percent. Thus, the optimization and standardization of technical parameters, following international recommendations, are sufficient to guarantee diagnostic quality and to reduce occupational exposures.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherPrograma de Pós-Graduação em Engenharia Biomédica
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectRadiação ionizante - Medidas de segurança
dc.subjectRadiação - Dosimetria - Testes
dc.subjectRadiação ionizante
dc.subjectPessoal da área médica - Avaliação de riscos
dc.subjectRadiologia pediátrica
dc.subjectSistema gastrointestinal - Radiografia
dc.subjectEsôfago
dc.subjectEstômago
dc.subjectDuodeno
dc.subjectFísica médica
dc.subjectIonizing radiation - Security measures
dc.subjectRadiation dosimetry - Testing
dc.subjectIonizing radiation
dc.subjectMedical personnel - Risk assessment
dc.subjectPediatric radiology
dc.subjectGastrointestinal system - Radiography
dc.subjectEsophagus
dc.subjectStomach
dc.subjectDuodenum
dc.subjectMedical physics
dc.titleAvaliação de dose ocupacional e parâmetros técnicos em seriografias de esôfago, estômago e duodeno pediátricas
dc.typemasterThesis


Este ítem pertenece a la siguiente institución