dc.contributorFilipov, Danielle
dc.contributorFilipov, Danielle
dc.contributorDia, Carla Roberta de Barros Rodrigues
dc.contributorConceição, André Luiz Coelho
dc.contributorSoboll, Danyel Scheidegger
dc.creatorTumellero, Micheli Scariot
dc.date.accessioned2020-11-12T16:13:30Z
dc.date.accessioned2022-12-06T14:11:06Z
dc.date.available2020-11-12T16:13:30Z
dc.date.available2022-12-06T14:11:06Z
dc.date.created2020-11-12T16:13:30Z
dc.date.issued2016-12-07
dc.identifierTumellero, Micheli Scariot. Avaliação da dose ocupacional no cristalino em procedimentos pediátricos de SEED após a otimização da proteção radiológica. 2016. 28 f. Trabalho de Conclusão de Curso (Graduação em Tecnologia em Radiologia) - Universidade Tecnológica Federal do Paraná, Curitiba, 2016.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/9700
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5242992
dc.description.abstractINTRODUCTION: The Barium Meal procedure is a fluoroscopic examination that is used to investigate pathologies of the gastrointestinal tract in children. To perform this examination, professionals remain inside the procedure room to position and immobilize the patient. Due to this fact, it is important to know the doses received by the professionals, since there are dose limits for each region of staff and to work in an optimized way, which is, taking into account the radiological protection and the diagnostic quality of the images. OBJECTIVES:To estimate, before and after the radiological protection optimization (through some modified parameters), the doses received by one professional in place of the lens.METHODOLOGY: Fourteen pairs of thermoluminescent dosimeters (TLDs) were hang from the ceiling to the lens region of a professional. A humanoid phantom was used to simulate a pediatric patient. The doses, obtained by the TLDs, were verifies before and after the changes in the parameters of the procedure, suggested by the application of the optimization. RESULTS:It was observed that, after the optimization of the radiological protection the parameters were appropriate with those proposed by the International Commission on Radiological Protection (ICRP). With the optimization, the dose received by the crystalline region was reduced in 46% and it was lower than the limit of 20mSv/year.CONCLUSIONS:It was observed that just changing some technical parameters of the examination, the occupational dose could the reduced to a value lower than the limit for the area.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherTecnologia em Radiologia
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectRadiação - Dosimetria
dc.subjectRadiologia médica
dc.subjectCrianças - Doenças - Diagnóstico
dc.subjectRadiologia
dc.subjectRadiation dosimetry
dc.subjectRadiology, Medical
dc.subjectChildren - Diseases - Diagnosis
dc.subjectRadiology
dc.titleAvaliação da dose ocupacional no cristalino em procedimentos pediátricos de SEED após a otimização da proteção radiológica
dc.typebachelorThesis