Voltammetric determination of sildenafil citrate in pharmaceuticals formulations

dc.creatorOrtiz, Reynaldo
dc.creatorNava, Lismar
dc.creatorMartínez, Yris J.
dc.creatorWeinhold, Elkis
dc.creatorParedes R., Andreina
dc.date2017-12-07T22:53:39Z
dc.date2017-12-07T22:53:39Z
dc.date2017-01
dc.date.accessioned2022-11-16T19:36:32Z
dc.date.available2022-11-16T19:36:32Z
dc.identifier0543-517X
dc.identifierhttp://www.saber.ula.ve/handle/123456789/44159
dc.identifierpp195802ME1003
dc.identifierppi201202ME4102
dc.identifier2244-8845
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5204314
dc.descriptionSe desarrolló un método voltamperométrico simple para la determinación de citrato de sildenafil (CS). El método se basa en la reducción catódica directa del CS sobre un electrodo de carbón vítreo modificado con una película plomo (Pb/ CV) en solución reguladora de acetato. La respuesta voltamperométrica de CS sobre Pb/CV, muestra dos picos uno a -1,15 y otro a -1,25 V. Los resultados experimentales indican una excelente correlación lineal entre la corriente de pico y la concentración, en un rango de 2×10-5 a 1,2×10-4 M para ambos picos. Los límites de detección (LOD) de CS fueron 1,1×10-6 y 5,2×10-6 M, usando voltametría de barrido lineal y voltametría de pulso diferencial, respectivamente. El método fue aplicado con éxito a la determinación de CS en formulaciones comerciales (comprimidos y tabletas orodispersables), encontrándose valores muy similares a los declarados por el fabricante; los resultados se contrastaron con los obtenidos por un método espectrofotométrico reportado y no se encontraron diferencias estadísticas significativas.
dc.descriptionA simple voltammetric method for the determination of sildenafil citrate (SC) was developed. The method is based on the direct cathodic reduction of SC on a lead film modified glassy carbon electrode (LF/GCE) in acetate buffer. Voltammetric response of SC at LF/GCE, shows two peaks at -1.15 V and -1.25 V. Experimental results indicate an excellent linear correlation between the peak current and concentration in the range of 2×10-5 to 1,2×10-4 M for both peaks. The detection limits (LOD) for SC were equal to 1.1×10-6 and 5.2×10-6 M, using Linear Sweep and Differential Pulse voltammetry, respectively. The method was successfully applied to the determination of SC in pharmaceutical formulations (Pills and Orodispersible tablets) and the contents were in close agreement with those quoted by the manufacturer. The results were compared with those obtained by a reported spectrophotometric method and no statistically significant differences were found.
dc.description7-16
dc.descriptionreynaldo@ula.ve
dc.descriptionymartin@ula.ve
dc.descriptionweinhold@ula.ve
dc.descriptionandrepar90@gmail.com
dc.descriptionSemestral
dc.formatapplication/pdf
dc.languagees
dc.publisherVenezuela
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.subjectElectrodo de película de plomo
dc.subjectCitrato de sildenafil
dc.subjectDeterminación
dc.subjectVoltametría
dc.subjectFacultad de Farmacia y Bioanálisis
dc.subjectLead film electrode
dc.subjectSildenafil citrate
dc.subjectDetermination voltammetry
dc.subjectRevista de la Facultad de Farmacia
dc.subjectRevista de la Facultad de Farmacia: Artículos Originales
dc.subjectMedicina y Salud
dc.subjectRevistas
dc.titleDeterminación voltamétrica de citrato de sildenafil en formulaciones farmacéuticas
dc.titleVoltammetric determination of sildenafil citrate in pharmaceuticals formulations
dc.typeinfo:eu-repo/semantics/article
dc.typeTexto


Este ítem pertenece a la siguiente institución