dc.contributorPérez, M.A.
dc.contributorGehrke S.A.
dc.contributorAramburú Júnior J.
dc.contributorPérez-Díaz Leticia, Universidad de la República (Uruguay). Facultad de Ciencias. Instituto de Biología.
dc.contributorDias do Prado T.
dc.contributorDedavid B. A.
dc.contributorMazon P.
dc.contributorDe Aza P. N.
dc.creatorGehrke, S.A.
dc.creatorAramburú Júnior, J.
dc.creatorPérez-Díaz, Leticia
dc.creatorDias do Prado, T.
dc.creatorDedavid, B.A.
dc.creatorMazón, P.
dc.creatorDe Aza, P.N.
dc.date.accessioned2022-06-01T12:38:52Z
dc.date.accessioned2022-10-28T20:22:35Z
dc.date.available2022-06-01T12:38:52Z
dc.date.available2022-10-28T20:22:35Z
dc.date.created2022-06-01T12:38:52Z
dc.date.issued2020
dc.identifierGehrke, S, Aramburú Júnior, J, Pérez-Díaz, L, [y otros] "Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations". PLos ONE. [en línea] 2020, 15 (5). 19 h. DOI: 10.1371/journal.pone.0233304
dc.identifier1932-6203
dc.identifierhttps://hdl.handle.net/20.500.12008/31774
dc.identifier10.1371/journal.pone.0233304
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4985581
dc.description.abstractObjectives The propose was to compare this new implant macrogeometry with a control implant with a conventional macrogeometry. Materials and methods Eighty-six conical implants were divided in two groups (n = 43 per group): group control (group CON) that were used conical implants with a conventional macrogeometry and, group test (group TEST) that were used implants with the new macrogeometry. The new implant macrogeometry show several circular healing cambers between the threads, distributed in the implant body. Three implants of each group were used to scanning electronic microscopy (SEM) analysis and, other eighty samples (n = 40 per group) were inserted the tibia of ten rabbit (n = 2 per tibia), determined by randomization. The animals were sacrificed (n = 5 per time) at 3-weeks (Time 1) and at 4-weeks after the implantations (Time 2). The biomechanical evaluation proposed was the measurement of the implant stability quotient (ISQ) and the removal torque values (RTv). The microscopical analysis was a histomorphometric measurement of the bone to implant contact (%BIC) and the SEM evaluation of the bone adhered on the removed implants. Results The results showed that the implants of the group TEST produced a significant enhancement in the osseointegration in comparison with the group CON. The ISQ and RTv tests showed superior values for the group TEST in the both measured times (3- and 4-weeks), with significant differences (p < 0.05). More residual bone in quantity and quality was observed in the samples of the group TEST on the surface of the removed implants. Moreover, the %BIC demonstrated an important increasing for the group TEST in both times, with statistical differences (in Time 1 p = 0.0103 and in Time 2 p < 0.0003). Conclusions Then, we can conclude that the alterations in the implant macrogeometry promote several benefits on the osseointegration process
dc.languageen
dc.publisherPublic Library of Science
dc.relationPLos ONE, 2020, 15(5): e0233304
dc.rightsLicencia Creative Commons Atribución (CC - By 4.0)
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)
dc.subjectExperimental implants
dc.subjectOsseointegration
dc.subjectBiomechanical phenomena
dc.subjectTitanium
dc.subjectProsthesis design
dc.titleCan changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations
dc.typeArtículo


Este ítem pertenece a la siguiente institución