dc.description.abstractAn electronic compensator of ratio errors and phase-displacements is proposed for in-service transformers. Neither an auxiliary winding nor auxiliary core is needed; and large variations of the load connected to the secondary winding are permitted, as it is required by the standards.
dc.publisherIEEE
dc.relationConference Digest Conference on Precision Electromagnetic Measurements, Ottawa, Ontario, Canada, , 2002
dc.rightsLas obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad De La República. (Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)
dc.subjectElectronic compensator
dc.subjectRatio errors
dc.subjectInstrument transformers
dc.subjectin-service transformers
dc.titleElectronic system for increasing the accuracy of in-service instrument-current transformers