dc.contributorMendoza Bobadilla, Jorge Luis
dc.creatorAlfaro Bermúdez, Frank Norbert
dc.creatorAranda Carbonell, Eder Eduardo
dc.date.accessioned2022-06-21T15:59:46Z
dc.date.accessioned2022-10-24T19:12:04Z
dc.date.available2022-06-21T15:59:46Z
dc.date.available2022-10-24T19:12:04Z
dc.date.created2022-06-21T15:59:46Z
dc.date.issued2022
dc.identifierhttp://dspace.unitru.edu.pe/handle/UNITRU/19644
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4751121
dc.description.abstractEn este presente trabajo de investigación se evaluó la remoción de sulfuros en un agua residual de pelambre proveniente de la Curtiembre Inversiones Junior S.A.C, utilizando una tecnología de oxidación avanzada con ozono a diferentes pH (9.5, 10.5 y 12.5) con un tiempo de tratamiento de 100 minutos; en un reactor de vidrio de 3 litros. Los resultados arrojaron que hubo mayor porcentaje de remoción de sulfuros de 99.55%, a un pH 9.5 y con una concentraciónde ozono de 0.6 g/h en el tiempo de 100 minutos, logrando reducir la mayor cantidad de sulfuro(S -2 <5ppm) lo cual cumple con los valores máximos admisibles (VMA) del Anexo N.º 02 para descargas de aguas residuales no domesticas evitando una contaminación en el sistema de alcantarillado según el D.S. Nº021-2009-VIVIENDA de nuestra Legislación Peruana. Adicionalmente, en esta investigación se logró obtener resultados de remoción de DQO y DBO de 69.27% y 98% respectivamente. Posteriormente, se evaluó la influencia de las variables de concentración de ozono y pH en el porcentaje de remoción de sulfuros, el cual el ANOVA realizado en Excel y Statgraphics muestra que la variable pH es la que influye significativamente en la remoción desulfuros con un 95% de nivel de confianza, mientras que la concentración de sulfuros no influyesignificativamente en dicha remoción.
dc.description.abstractIn this present research work, the removal of sulfides in a residual water of unhairing from Curtiembre Inversiones Junior S.A.C was evaluated, using an advanced oxidation technology with ozone at different pH (9.5, 10.5 and 12.5) with a treatment time of 100 minutes; in a 3 liter glass reactor. The results showed that there was a higher percentage of sulfide removal of 99.55%, at a pH of 9.5 and with an ozone concentration of 0.6 g/h in a time of 100 minutes, managing to reduce the greatest amount of sulfide (S-2<5ppm) which complies with the maximum admissible values (VMA) of Annex No. 02 for non-domestic wastewater discharges, avoiding contamination in the sewage system according to D.S. Nº021-2009- HOUSING of our Peruvian Legislation. Additionally, in this investigation it was possible to obtain COD and BOD removal results of 69.27% and 98% respectively. Subsequently, the influence of the variables of ozone concentration and pH in the percentage of sulfide removal was evaluated, which the ANOVA carried out in Excel and Statgraphics shows that the pH variable is the one that significantly influences the removal of sulfides with a 95 % confidence level, while the concentration of sulfides does not significantly influence said removal.
dc.languagespa
dc.publisherUniversidad Nacional de Trujillo
dc.publisherPE
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.sourceUniversidad Nacional de Trujillo
dc.sourceRepositorio Institucional - UNITRU
dc.subjectPelambre
dc.subjectoxidación avanzada
dc.subjectozono
dc.subjectremoción de sulfuros
dc.subjectagua residual de pelambre
dc.subjectcontaminación
dc.subjectcurtiembre
dc.subjectsulfuro
dc.titleInfluencia de la concentración de ozono y pH en la remoción de sulfuros en efluentes de pelambre de curtiduría
dc.typeinfo:eu-repo/semantics/bachelorThesis


Este ítem pertenece a la siguiente institución