dc.identifierChririnos, J. C. (2016). Efecto de la energía de compactación en la densidad seca máxima y contenido óptimo de humedad del suelo granular de la cantera El Gavilán, 2015 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de http://hdl.handle.net/11537/10377
dc.identifier624 CHIR 2016
dc.identifierhttps://hdl.handle.net/11537/10377
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4728169
dc.description.abstractRESUMEN La presente investigación tuvo la finalidad de analizar el material proveniente de la cantera El Gavilán con el objetivo de determinar la influencia de la energía de compactación con respecto a la densidad seca máxima y óptimo contenido de humedad. Para el desarrollo de la investigación se realizó los ensayos generales para clasificar el suelo mediante el sistema AASHTO (American Association of State Highway and Transportation Officials), con los resultados del ensayo de granulometría se determinó el método C del tipo de compactación Proctor Modificado para compactar el suelo; en el Proctor Modificado se varió la energía de compactación, empezando con 56 golpes por capa, establecido en la norma técnica ASTM D-1557, hasta los 61 golpes por capa haciendo esta variación de un golpe por cada capa en cada uno de los ensayos realizados. Se determinó que el material granular requiere de una mayor energía de compactación para obtener la densidad seca máxima y el óptimo contenido de humedad con respecto a lo mencionado por la norma técnica ASTM D-1557, determinándose una variación de 0.97 kg/cm 2 en la energía de compactación. Se concluye que la densidad seca máxima obtenida fue 2.18 gr/cm y el óptimo contenido de humedad de 3.5%, se obtiene con 28.24 kg/cm de energía de compactación correspondiente a 58 golpes por capa.
dc.description.abstractABSTRACT The following investigation was intended to analyze the material from the quarry The Hawk order to determine the influence of compaction energy with respect to the maximum dry density and optimum moisture content. For the development of research rehearsals we were performed to classify the soil by AASHTO system (American Association of State Highway and Transportation Officials), with assay results grading method C type compaction Modified Proctor was determined to compact the floor in the modified Proctor compaction energy was varied, starting with 56 blows, established in the technical standard, up to 61 strokes per layer by this variation of one stroke for each layer in each of the tests performed by layer. It was determined that the granular material requires more energy compaction for maximum dry density and optimum moisture content relative to that mentioned by the technical ASTM D-1557, determining a variation of 0.97 kg/cm in energy compaction . It is concluded that the maximum dry density obtained was 2.18 g/cm and the optimum moisture content of 3.5%, is obtained with 28.24 kg/cm2 energy corresponding to 58 strokes per layer compaction.
dc.languagespa
dc.publisherUniversidad Privada del Norte
dc.publisherPE
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/3.0/us/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
dc.sourceUniversidad Privada del Norte
dc.sourceRepositorio Institucional - UPN
dc.subjectCompactación de suelos
dc.subjectSuelos
dc.subjectCanteras
dc.titleEfecto de la energía de compactación en la densidad seca máxima y contenido óptimo de humedad del suelo granular de la cantera El Gavilán, 2015