dc.contributor | Encalada Ruíz, Patricio Germán | |
dc.contributor | Delgado Oleas, Gabriel Alfonso | |
dc.contributor | Gavilanes García, Javier José | |
dc.creator | Cazco Barba, Luisa Cristina | |
dc.date.accessioned | 2020-03-10T14:29:13Z | |
dc.date.accessioned | 2022-10-20T19:01:46Z | |
dc.date.available | 2020-03-10T14:29:13Z | |
dc.date.available | 2022-10-20T19:01:46Z | |
dc.date.created | 2020-03-10T14:29:13Z | |
dc.date.issued | 2020-02-28 | |
dc.identifier | Cazco Barba, Luisa Cristina. (2020). Diseño e implementación de un sistema automático de suministro trifásico permanente y optimización del consumo energético para la Avícola “Flor María”. Escuela Superior Politécnica de Chimborazo. Riobamba. | |
dc.identifier | http://dspace.espoch.edu.ec/handle/123456789/13928 | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4583872 | |
dc.description.abstract | In the "Flor María" Avicola, an automatic transfer system for permanent three-phase electricity supply was designed and implemented, in energy consumption from the public network. Empresa E1éctrica Riobamba (EERSA). An automatic transfer board commanded by a Lovato ATL 610 controller was used that guaranteed the power supply of the EERSA or the Generator (MODASA MP- 110), a Lovato DCRL 8 controller that corrected the low power factor present in the network, due to the high variable and inductive load, and an HMI screen that monitored the generation of energy in peak hours over 50 kw. As a result, a power factor of 0.98, response time of 5 seconds, reduction of active power consumption 18.80%, apparent power 23.81%, reactive power 53.21 % was obtained. The implementation improved the power factor in different consumptions, allowed the generation of electricity during peak hours and reduced annual energy consumption costs to 20.26%, an annual energy saving of 7.13% and a decrease in annual diesel consumption by 80% The realization of the relevant maintenance in the autonomous system, allowed the correct balance of loads giving an ideal operation, eradicating possible failures. | |
dc.language | spa | |
dc.publisher | Escuela Superior Politécnica de Chimborazo | |
dc.relation | UDCTIPEC;20T01312 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/3.0/ec/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | TECNOLOGÍA Y CIENCIAS DE LA INGENIERÍA | |
dc.subject | CONTROL AUTOMÁTICO | |
dc.subject | AUTOMATIZACIÓN PLANTA AVÍCOLA | |
dc.subject | CORRECCIÓN FACTOR DE POTENCIA | |
dc.subject | SUMINISTRO ENERGÉTICO PERMANENTE | |
dc.subject | TRANSFERENCIA AUTOMÁTICA | |
dc.title | Diseño e implementación de un sistema automático de suministro trifásico permanente y optimización del consumo energético para la Avícola “Flor María”. | |
dc.type | Tesis | |