dc.description.abstract | El tubo Venturi es un dispositivo utilizado para medir
el caudal en diferentes procesos de la industria. En
el presente trabajo, se realiza un estudio para dos
casos, uno experimental y otro numérico de la presión
ejercida por el flujo de agua en las paredes de un
tubo Venturi. En el primer caso, se realizan cinco
experimentos con diferentes caudales. En el segundo,
el flujo se simula para dos tipos de mallas y dos modelos
de turbulencia, utilizando el código COMSOL
Multhiphysics 4.3. Los resultados experimentales y
numéricos mostraron que las presiones del flujo sobre
las paredes en dos referencias identificadas C
y G mantienen constante su magnitud; además, los
perfiles numéricos mostraron que la menor caída de
presión se presenta en la pared a la entrada y salida
de la sección de la garganta. Se concluye que, la distribución
de la presión del flujo en la pared de la
sección de la garganta tiene un perfil convexo, y los
resultados de presiones obtenidos para el modelo de
turbulencia k-e estándar, se ajustan más a los datos
experimentales.//The Venturi tube is a device used to measure the flow
rate in different industrial processes. In the present
work, a study is carried out for two cases, one experimental
and another numerical of the pressure exerted
by the flow of water on the walls of a Venturi tube.
In the first case, five experiments with different flow
rates are carried out. In the second, the flow is simulated
for two types of meshes and two turbulence
models, using the code COMSOL Multhiphysics 4.3.
The experimental and numerical results showed that
the pressures of the flow on the walls in two references
identified as C and G keep their magnitude constant;
in addition, the numerical profiles showed that the
lowest pressure drop occurs in the wall at the inlet
and outlet of the throat section. It is concluded that,
the distribution of the flow pressure in the wall of the
throat section has a convex profile, and the results of
pressures obtained for the standard k − e turbulence
model are more adjusted to the experimental data. | |
dc.language | spa | |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/ec/ | |
dc.rights | openAccess | |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 Ecuador | |
dc.subject | flujo de agua; Water flow | |
dc.subject | modelo de turbulencia; Turbulence model | |
dc.subject | presión; Pressure | |
dc.subject | simulación; Simulation | |
dc.subject | tubo Venturi; Venturi tube | |
dc.title | Estudio experimental y numérico de la presión del flujo de agua en un tubo Venturi | |
dc.type | Article | |