dc.creatorTalio, María Carolina
dc.creatorAlesso, Magdalena
dc.creatorAcosta, Mariano
dc.creatorOlsina, Roberto Antonio
dc.creatorFernandez, Liliana Patricia
dc.date.accessioned2019-12-23T19:09:00Z
dc.date.accessioned2022-10-15T15:47:28Z
dc.date.available2019-12-23T19:09:00Z
dc.date.available2022-10-15T15:47:28Z
dc.date.created2019-12-23T19:09:00Z
dc.date.issued2013-05
dc.identifierTalio, María Carolina; Alesso, Magdalena; Acosta, Mariano; Olsina, Roberto Antonio; Fernandez, Liliana Patricia; Determination of cadmium in tobacco by solid surface fluorescence using nylon membranes coated with carbon nanotubes; Elsevier Science; Talanta; 107; 5-2013; 61-66
dc.identifier0039-9140
dc.identifierhttp://hdl.handle.net/11336/92841
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4404930
dc.description.abstractA new methodology based on fluorescent signal enhancement of o-cresolphthalein (o-CPT) for traces of cadmium determination is proposed. The dye was retained on membrane filters in the presence of a micellar surfactant solution of carbon nanotubes (CNTs). All the experimental variables that influence both the preconcentration procedure and the fluorimetric sensitivity were carefully optimized. The calibration graph using zeroth order regression was linear from 6.5 ng L-1 to 5.65×105 ng L -1, with a correlation coefficient higher than 0.999. Under optimal conditions, the limits of detection and quantification were of 2 ng L -1 and 6.5 ng L-1. respectively. The proposed method showed good sensitivity and selectivity, with good tolerance to foreign ions, and it was applied to the determination of trace amounts of cadmium in leachate from cigarettes' tobacco samples with satisfactory results. The trueness of the recommended procedure was assessed through parallel analysis of the samples with electrothermal atomization atomic absorption spectrometry. This methodology represents an innovative and attractive application of membrane filters that enables metal traces determination by solid surface fluorescence.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S003991401201082X
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2012.12.048
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectCADMIUM TRACES
dc.subjectCARBON NANOTUBES
dc.subjectCIGARETTES TOBACCO LEACHATE
dc.subjectO-CRESOLPHTHALEIN
dc.subjectSOLID SURFACE FLUORESCENCE
dc.titleDetermination of cadmium in tobacco by solid surface fluorescence using nylon membranes coated with carbon nanotubes
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución