dc.creatorVillalonga, Anabel
dc.creatorVegas, Borja
dc.creatorPaniagua, Gonzalo
dc.creatorEguílaz Rubio, Marcos
dc.creatorMayol, Beatriz
dc.creatorParrado, Concepción
dc.creatorRivas, Gustavo Adolfo
dc.creatorDíez, Paula
dc.creatorVillalonga, Reynaldo
dc.date.accessioned2021-08-03T17:20:41Z
dc.date.accessioned2022-10-15T13:45:24Z
dc.date.available2021-08-03T17:20:41Z
dc.date.available2022-10-15T13:45:24Z
dc.date.created2021-08-03T17:20:41Z
dc.date.issued2020-11
dc.identifierVillalonga, Anabel; Vegas, Borja; Paniagua, Gonzalo; Eguílaz Rubio, Marcos; Mayol, Beatriz; et al.; Amperometric aptasensor for carcinoembryonic antigen based on a reduced graphene oxide/gold nanoparticles modified electrode; Elsevier Science SA; Journal of Electroanalytical Chemistry; 877; 114511; 11-2020; 1-7
dc.identifier1572-6657
dc.identifierhttp://hdl.handle.net/11336/137689
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4392954
dc.description.abstractWe report the construction of a novel amperometric aptasensor for the highly specific detection of carcinoembryonic antigen (CEA). The sensing interface was assembled by electrodeposition of reduced graphene oxide (rGO) and gold nanoparticles (AuNPs) on a carbon screen-printed electrode (SPE) and further functionalization with a biotin and thiol-modified anti-CEA DNA hairpin aptamer. The sensing approach relies on the specific recognition of CEA by the folded aptamer, causing unfolding of the DNA hairpin structure and unmasking the biotin residues at the aptamer chain. Further incubation with a sptreptavidin-peroxidase conjugate allows the amperometric detection of the cancer biomarker. This aptasensor was able to detect CEA in the broad range from 20 pg mL−1 to 2 μg mL−1 (112 fM–11 μM) with a detection limit of 16 pg mL−1 (90 fM). The aptasensor also showed high reproducibility, specificity and stability, and was successfully validated in diluted human serum samples.
dc.languageeng
dc.publisherElsevier Science SA
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S1572665720307384
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.jelechem.2020.114511
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectAPTAMER
dc.subjectBIOSENSOR
dc.subjectCARCINOEMBRYONIC ANTIGEN
dc.subjectGOLD NANOPARTICLES
dc.subjectGRAPHENE
dc.titleAmperometric aptasensor for carcinoembryonic antigen based on a reduced graphene oxide/gold nanoparticles modified electrode
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución