dc.creator | Garrido, Mariano Enrique | |
dc.creator | Lista, Adriana Guillermina | |
dc.creator | Palomeque, Miriam Edid | |
dc.creator | Fernández Band, Beatriz Susana | |
dc.date.accessioned | 2020-02-07T18:44:51Z | |
dc.date.accessioned | 2022-10-15T13:09:01Z | |
dc.date.available | 2020-02-07T18:44:51Z | |
dc.date.available | 2022-10-15T13:09:01Z | |
dc.date.created | 2020-02-07T18:44:51Z | |
dc.date.issued | 2002-11 | |
dc.identifier | Garrido, Mariano Enrique; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana; Fluorimetric determination of fluoride in a flow assembly integrated on-line to an open/closed FIA system to remove interference by solid phase extraction; Elsevier Science; Talanta; 58; 5; 11-2002; 849-853 | |
dc.identifier | 0039-9140 | |
dc.identifier | http://hdl.handle.net/11336/96901 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4389658 | |
dc.description.abstract | A simple flow injection fluorimetric method for fluoride determination is proposed. The method is based on the enhanced fluorescence of quercitin-Zr(IV) complex when fluoride ion is present in the sample. An open/closed FIA manifold with a mini-column of Dowex 50W X8 resin was used to remove the most important interference (aluminum). The two FIA assemblies were integrated on-line to automate the pretreatment of the water sample and fluoride determination. The calibration graph was linear over the range 0.1-3.0 μg ml-1 of fluoride with a correlation coefficient of 0.999 and LOD 0.06 μg ml-1. The relative standard deviation was 2.5% and the sample throughput was 52 h-1 without pretreatment and 10 h-1 with pretreatment of the sample. The method was applied to the determination of fluoride in water samples. | |
dc.language | eng | |
dc.publisher | Elsevier Science | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/S0039-9140(02)00397-1 | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914002003971 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | FLUORIMETRIC | |
dc.subject | OPEN/CLOSED FIA SYSTEM | |
dc.subject | SOLID PHASE EXTRACTION | |
dc.title | Fluorimetric determination of fluoride in a flow assembly integrated on-line to an open/closed FIA system to remove interference by solid phase extraction | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |