dc.creatorGarrido, Mariano Enrique
dc.creatorLista, Adriana Guillermina
dc.creatorPalomeque, Miriam Edid
dc.creatorFernández Band, Beatriz Susana
dc.date.accessioned2020-02-07T18:44:51Z
dc.date.accessioned2022-10-15T13:09:01Z
dc.date.available2020-02-07T18:44:51Z
dc.date.available2022-10-15T13:09:01Z
dc.date.created2020-02-07T18:44:51Z
dc.date.issued2002-11
dc.identifierGarrido, Mariano Enrique; Lista, Adriana Guillermina; Palomeque, Miriam Edid; Fernández Band, Beatriz Susana; Fluorimetric determination of fluoride in a flow assembly integrated on-line to an open/closed FIA system to remove interference by solid phase extraction; Elsevier Science; Talanta; 58; 5; 11-2002; 849-853
dc.identifier0039-9140
dc.identifierhttp://hdl.handle.net/11336/96901
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4389658
dc.description.abstractA simple flow injection fluorimetric method for fluoride determination is proposed. The method is based on the enhanced fluorescence of quercitin-Zr(IV) complex when fluoride ion is present in the sample. An open/closed FIA manifold with a mini-column of Dowex 50W X8 resin was used to remove the most important interference (aluminum). The two FIA assemblies were integrated on-line to automate the pretreatment of the water sample and fluoride determination. The calibration graph was linear over the range 0.1-3.0 μg ml-1 of fluoride with a correlation coefficient of 0.999 and LOD 0.06 μg ml-1. The relative standard deviation was 2.5% and the sample throughput was 52 h-1 without pretreatment and 10 h-1 with pretreatment of the sample. The method was applied to the determination of fluoride in water samples.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/S0039-9140(02)00397-1
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0039914002003971
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFLUORIMETRIC
dc.subjectOPEN/CLOSED FIA SYSTEM
dc.subjectSOLID PHASE EXTRACTION
dc.titleFluorimetric determination of fluoride in a flow assembly integrated on-line to an open/closed FIA system to remove interference by solid phase extraction
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución