dc.creatorSansinena, Marina Julia
dc.creatorSantos, Maria Victoria
dc.creatorZaritzky, Noemi Elisabet
dc.creatorBaeza, Rosa Isabel
dc.creatorChirife, Jorge
dc.date.accessioned2021-05-26T15:20:17Z
dc.date.accessioned2022-10-15T12:49:57Z
dc.date.available2021-05-26T15:20:17Z
dc.date.available2022-10-15T12:49:57Z
dc.date.created2021-05-26T15:20:17Z
dc.date.issued2010-05
dc.identifierSansinena, Marina Julia; Santos, Maria Victoria; Zaritzky, Noemi Elisabet; Baeza, Rosa Isabel; Chirife, Jorge; Theroretical prediction of the effect of heat transfer parameters on cooling rates of liquid-filled plastic straws used for cryopreservation os spermatozoa; Cryo Letters; Cryo-letters; 31; 2; 5-2010; 120-129
dc.identifier0143-2044
dc.identifierhttp://hdl.handle.net/11336/132562
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4388006
dc.description.abstractHeat transfer plays a key role in cryopreservation of liquid semen in plastic straws. The effect of several parameters on the cooling rate of a liquid-filled polypropylene straw when plunged into liquid nitrogen was investigated using a theoretical model. The geometry of the straw containing the liquid was assimilated as two concentric finite cylinders of different materials: the fluid and the straw; the unsteady-state heat conduction equation for concentric cylinders was numerically solved. Parameters studied include external (convection) heat transfer coefficient (h), the thermal properties of straw manufacturing material and wall thickness. It was concluded that the single most important parameter affecting the cooling rate of a liquid column contained in a straw is the external heat transfer coefficient in LN2. Consequently, in order to attain maximum cooling rates, conditions have to be designed to obtain the highest possible heat transfer coefficient when the plastic straw is plunged in liquid nitrogen.
dc.languageeng
dc.publisherCryo Letters
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.cryoletters.org/Abstracts/vol_31_2_2010.htm#120
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectTheoretical
dc.subjectHeat conduction
dc.subjectThermal diffusivity
dc.subjectSpermatozoa
dc.subjectStraw
dc.titleTheroretical prediction of the effect of heat transfer parameters on cooling rates of liquid-filled plastic straws used for cryopreservation os spermatozoa
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución